Setting The Asa; Checking For Running Time - AAton XTRprod User Manual

Hide thumbs Also See for XTRprod:
Table of Contents

Advertisement

of the normal gate cleaning procedure, clean this area with a Q-tip
and lens cleaning fluid to assure that no dust particles cover the
LED array.
The seven diodes will illuminate in test position whether or not ti-
mecode is running in the camera.

8.7.2 Setting the ASA

When changing magazines, make sure the ASA/ISO setting of the
camera matches the film stock being used. To check the current ASA
selection on the LCD control panel, press the button marked ISO
twice . To adjust the ASA setting, press SET, then this button. Make
your selection between 25 and 1000 ISO by toggling the button or
by rotating the jog wheel.

7.7.3 Checking for Running Time

The yellow LED located to the right of the motor, will flash once
per second on the second when timecode is running in the camera.
Get into the habit of looking for this flash as an additional peace of
mind check. If more than one camera is counting time on the set,
check that all flashes occur simultaneously.
102

Advertisement

Table of Contents
loading

Table of Contents