36" Gas Downdraft Cooktop –
Ductwork Preparation
Ventilation unit comes detached from cooktop.
To ensure proper installation, refer to 36" Gas Downdraft
Cooktop Specifications page for planning information, and
installation guide on web for complete installation details
including countertop and cabinet requirements.
Ducting Options
On floor, through floor or through wall.
Exhaust Outlet Locations –
Cut exhaust outlet hole in wall or
floor based on desired installation.
Exhaust duct MUST be located
between wall studs or floor joists.
Built-In Cooktop Ductwork Preparation
Ventilation unit comes detached from cooktop. To ensure proper
installation, refer to 36" Gas Downdraft Cooktop Specifications page
for planning information, and installation guide on web for complete
installation details including countertop and cabinet requirements.
Ducting Options – On floor, through floor or through wall.
Ventilation Unit Discharge Options – Left, right or down.
Consider ductwork location and desired installation before cutting
exhaust outlet hole in cabinet. For proper installation, cooktop
exhaust duct MUST be located between wall studs or floor joists.
Vent exhaust air outside only and NOT into any concealed space.
Exhaust Duct Required – Galvanized or aluminum duct in 6" round
or 3-1/4" x 10" rectangular, or combination of both. PVC should
be used if installing under concrete slab.
Local building code must be followed in specifying approved type
and schedule of ALL duct used; always use appropriate roof or
wall cap with damper.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
RC36DG60P 07/13
Cabinet
side wall
Cutout
center
6"
4
/
"
7
16
Bottom
Exhaust Outlet
1-800-FRIGIDAIRE
frigidaire.com
1-800-265-8352
frigidaire.ca
© 2013 Electrolux Home Products, Inc.
Built-In Downdraft Cooktop
Electrical / Gas Supply Location
11
/
"
1
5
1
/
"
2
2
6"
8
/
"
3
4
Recomm.
gas supply
stub area
4"
C L
16
/
15
/
"
1
4
Left or Right
Exhaust Outlets
For maximum efficiency, use shortest, straightest duct run possible.
Unit operates most efficiently with up to 100 equivalent feet of duct.
(Refer to Calculating Duct Length Table in Product Installation Guide.)
Flexible ducting is not recommended due to severely restricted
airflow; if blower outlet and floor or wall duct location do NOT align,
flexible METAL ducting can be used to adapt to offset.
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold. Cold weather installations should
have additional backdraft damper installed.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Accessories information available
RC36DG60PS
Countertop
surface
Cabinet
side wall
Electrical
Installation Note:
Locate 120 volt,
60 Hertz, properly
grounded branch
circuit protected
by 15 amp circuit
breaker or time
delay fuse within
shaded area
shown.
Cutout
center
/
"
1
"
4
16
/
"
1
6"
4
on the web at frigidaire.com