Fig. 11
Once the door has been correctly aligned, tighten
the holding nuts on the fixing brackets and attach the
appliance to the adjacent units and the bottom of the
work surface (Fig. 11).
Fig. 12
If the appliance has been fitted into a space 820 mm
high and the maximum height of the base plate is
100 mm, fit the front cover plate by pushing the two
vertical lugs into the rectangular holes on the bottom
side of the ventilation duct until they click. The plate
can be adjusted backwards or forwards in the holes
(Fig. 12).
Fig. 13
If the base plate is between 100 and 135 mm high,
cut it as shown in Fig. 14 and mount as described
above. If the base plate is between 135 and 170 mm
high, cut it as shown in Fig. 12.
Fig. 14
If the appliance has been fitted into a space 870 mm
high and the maximum height of the base plate is
150 mm, fit the front cover plate as described in Fig.
13. If the base plate is between 150 and 185 mm
high, cut it as shown in Fig. 14. If the base plate is
between 185 and 220 mm high, cut it as shown in
Fig. 12.

Electrical connection

Before plugging in, ensure that the voltage and frequency shown on the serial number plate correspond
to your domestic power supply. Voltage can vary by ±6% of the rated voltage. For operation with
different voltages, a suitably sized auto-transformer must be used.
The technical data is indicated in the rating plate on the left side inside the appliance.
TECHNICAL SPECIFICATIONS
D517
820
870
170
220
D518
min.
2
50cm
D546
D520
Fig. 11
Fig. 12
135
185
Fig. 13
820
870
100
150
Fig. 14
820
870
100 135
150 185
GB
39

Advertisement