Connections With The Vm-7200/7100 - Roland RPC-1 Owner's Manual

R-bus interface card
Table of Contents

Advertisement

Connections with other R-BUS devices
VM-3100Pro Quick Setup
By using Quick Setup, you can instantly recall settings for
use with a connected RPC-1. At this time, settings for
remotely controlling your sequencer software will also be
recalled. The following types of Quick Setup are available.
Software to be controlled
Logic Audio
Cakewalk
Cubase VST
When you perform one of the above operations, the display
will ask "Load xxxx Configuration?" (xxxx is either LOGIC,
CAKEWALK, or CUBASE). Press [ENTER/YES].
When Quick Setup is executed, the following parameters and
routings will be changed.
Parameter
Value set
M.clk Select
RMDB-2
Master Source
MIX
LocatorType
MEASURE
Control Type
Off
Timing Mon.
MEASURE
Beat
4/4
R-BUS Target
RPC-1
Transport
USER1
ShiftKey
OFF or C-1
USER1
Settings for
each program
EZR SEL
RMDB DIRECT
14
Setting method
[SHIFT] + [F1]
[SHIFT] + [F2]
[SHIFT] + [F3]
Location
Explanation
[Shift] + [Digital
Set as slave of
in]
RPC-1
Master [Select]
VM-3100Pro moni-
tors the signal sent
to the RPC-1
[System]
Use locator to trans-
mit SPP
[System]
Don't transmit Audio
[F1-F4]
[MIDI]
fader values
[System]
Measure is received
[F1-F4]
[MIDI]
as timing data
[System]
4/4 time signature
[F1-F4]
[MIDI]
[System]
Connect with RPC-1
[F1-F4]
[MIDI]
[System]
Transmit USER1
[F1-F4]
[MIDI]
note
[System]
OFF for Logic. Oth-
[F1-F4]
[MIDI]
erwise, C-1
[System]
Overwrite to USER1
[F1-F4]
[MIDI]
[F1-F4]
[EZ Routing]
Send Input 1–8 to
R-BUS

Connections with the VM-7200/7100

In order to connect the VM-7200/7100 with the RPC-1, the
VM-24E I/O expansion board (an expansion board that adds
an R-BUS connector) must be installed in the VM-7200/7100.
Updating the system program
In order for the VM-7200/7100 to be connected and used
with the RPC-1, system program version 1.60 or later is
required.If your VM-7200/7100 has version 1.50 or earlier,
you must update the system program.
Checking the version
After starting up the VM-7200/7100 system, press
[on Display] and [9]. Unit 1/2 Version is the version of the
VM-7200/7100.
Updating the system program
The directory "UPDATE > VM-7000" in the included
"Drivers/Update" CD-ROM contains the data for the update.
Perform the update procedure as directed by the
"readme.doc" file.
Example settings
RPC-1 settings (in the Control Panel)
• Master Clock: Int. Clock
• Int. Clock Sample Rate: either 32, 44.1, or 48 kHz
VM-C7200/7100 settings
• WORD CLOCK SOURCE: MULTI 1-8
Use the VM-7200/7100 patchbay to assign the inputs of the
VM-7200/7100 to the RPC-1.
The output of the RPC-1 will be input to MULTI-IN. You can
also use multiple RPC-1 units simultaneously. For details
refer to p. 17 "Using multiple RPC-1 units."

Advertisement

Table of Contents
loading

Table of Contents