Air Filter; Fuel Filter - Echo HCA-266 Operator's Manual

Shaft hedge clipper
Hide thumbs Also See for HCA-266:
Table of Contents

Advertisement

HCA-266
3. Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.
* Replacement is recommended based on the finding of damage or wear during inspection.

Air Filter

Level 1.
Parts Required:
REPOWER
1. Close choke (Cold Start Position [
from entering the carburetor throat when the air filter is
removed. Brush accumulated dirt from air cleaner area.
2. Remove air filter cover and air filter retainer from inside
cover. Brush dirt from inside cover.
3. Replace filter if it is damaged, very dirty, or the rubber sealing edges are deformed.
4. Remove foam pre-filter and air filter and clean as indicated
below:.
Foam Pre-filter
• Clean foam filter in water/detergent solution and rinse with
clean water.
• Wrap the filter in a clean, dry cloth and squeeze (do not
wring) dry. Allow to dry completely before reuse. Do not oil.
Dual Layer Air Filter
• Lightly brush debris from filter.
• Soak heavily soiled filters in water/detergent solution to loosen dirt, then brush lightly.
• Rinse with clean water and allow to dry completely before reuse.
5. Place foam pre-filter over raised center and inside outer lip of air filter. Install air filter in air filter case.
6. Install air filter retainer on post in air filter cover, flat side up.
7. Install air filter cover and tighten cover knob securely.

Fuel Filter

Level 1.
Parts Required:
REPOWER
Fuel is VERY flammable. Use extreme care when mixing,
storing or handling, or serious personal injury may result.
1. Use a clean rag to remove loose dirt from around fuel cap
and empty fuel tank.
2. Use a hook to pull the fuel line and filter fromthe tank.
3. Remove the filter from the line and install the new filter.
X7502026404
© 08/2013 ECHO Inc.
TM
AIR & FUEL FILTER KIT.
]). This prevents dirt
TM
AIR & FUEL FILTER KIT.
MAINTENANCE
23

Advertisement

Table of Contents
loading