installations, ensure that the liner is
securely connected to the insert flue collar.
Tile Liner
Steel Plate
Sealing Plate
Masonry Direct Connect Installation
less expensive than the other methods. A steel block-off
plate is used to seal off the chimney and allow the chim-
ney connector to pass through and extend into the begin-
ning of the tile flue liner. If the steel plate is impractical
because of some odd fireplace construction, fiberglass
insulation may be packed around the chimney connector.
this is the method used, a chimney cap is recommended
to prevent the fiberglass from being exposed to the rain.
greater than 3 times that of the insert which is 28.27 sq.
in. it is recommended that a positive connect installation
be used.
Chimney Cap
Masonry Positive Connect Installation
damaged beyond repair or the chimney has historically
had low draft problems. The liner listed to UL-1777 can
be rigid or flexible with a chimney cap and top sealing
plate installed
Exception F200 Wood Insert
This method is most commonly used because it is
To seal the flue from the living space of the home, if
If the masonry chimney flue cross-sectional area is
This method is recommended when the tile linner is