Download Print this page

Thermador VCH36 Installation Instructions page 4

Cooker hood

Advertisement

VCH54 Mounting Plate
FIGURE 3
(not to scale) Top View
Rear
7
11-
/
"
8
5
11-
/
"
16
Front
Required clearance for PLENUM transition.
FIGURE 4
29
10"
Plemum and Island Hood
2. Prepare cabinet or soffit by tapping holes for mounting
filter housings. Figure 2 and Figure 3 show the top view
of the VCH36 and VCH54 respectively. Each figure
shows mounting hole locations, overall size of filter
housing mounting plate, and required clearance for the
transition. See Figure 4 for the clearance required for
the PLENUM transition in the VCH54 installation.
3. Attach transition to filter housing and seal with duct
tape. The VCH36 requires the VCHTR1O transition.
The VCH54 requires the VCHTR10 and PLENUM
transitions.
Thermador reserves the right to change specifications or design without notice. Some models are certified for use in Canada.
Thermador is not responsible for products which are transported from the United States for use in Canada. Check with your local
Canadian distributor or dealer. Thermador, 5551 McFadden Avenue, Huntington Beach, CA 92649.
LISTED #157J
3
18-
/
4
VCHTR10
Transition
54"
-
1
/
"
2
1
-
10
/
8
ECO71532 • 19-19-488D • © Thermador Corporation,1998 • Litho in U.S.A. 8/99
"
19-
C L
7
10-
/
"
8
1
1-
/
"
2
7
21-
/
Light
Controller
B
"
VCH36 Wiring (VCH54 has three 75-watt lamps)
4. Attach filter housing to prepared cabinet/soffit surface
using wood screws provided. The installation requires
two people due to the size of the unit.
5. Run Conduit for wires to mounting top plate and
connect using proper connectors. Remove wiring com-
partment cover (accessible through filter housing) and
connect wires as shown in Figure 5. The light switch is
supplied by the electrical contractor.
6. For the remote blower installation follow the instruc-
tions supplied with the remote blower.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800/735-4328
Page 4
1
/
"
2
5
1-
/
"
8
7
/
"Diameter
8
"
8
1
25-
/
"
2
FIGURE 5
G
75 Watt
Lamp
Mounting hole
locations (12
places)
Power
Supply
L
N
G
W
75 Watt
Lamp

Advertisement