Mitsubishi Electric WD-60735 Service Manual page 24

Dlp projection hdtv
Hide thumbs Also See for WD-60735:
Table of Contents

Advertisement

MODELS: WD-60735 / WD-60C8 / WD-65735 / WD-65736 / WD-65835 / WD-65C8 / WD-73735 /
LED Indicator Diagnostics
The front panel LEDs provide an indication of the set's operation, and the possible cause of a malfunction. There are three
front panel LEDs, "Power", "Status" and "Lamp". The LED display shows the current status or indicates a possible
malfunction.
Pow e r/Tim e r
LED
Off
Fast Blink
Green
Off
Green
Slow B linking
Green
Pow er/Tim e r
LED
Off
Off
Off
Off
Off
* A red Lamp LED only occurs after 2 attempts to light the lamp.
Each attempt (pressing POW ER) must be at least 65 seconds apart.
During each attem pt ballast striking may be audible.
3. Error Code Operational Check
Note: The TV must be in "Shut Down" and not have been switched Off, to perform the Error Code Opera-
tional Check. When the TV is switched Off, the code automatically resets to "12" No Error.
Pressing the front panel "INPUT" and "MENU" buttons at the same time, and holding for 5 seconds,
activates the Error Code Mode. The "TIMER LED" flashes denoting a two digit Error Code, or indicating no
problem has occurred since the last Initialization.
Note: The front panel buttons must be used, NOT those on the Remote Control.
The number of flashes indicates the value of the MSD (tens digit) of the Error Code.
The flashing then pauses for approximately 1/2 second.
The LED then flashes indicating the value of the LSD (ones digit) of the Error Code.
The Error Code is repeated a total of 5 times.
Example: If the Error Code is "23", the LED will flash two times, pause, and then flash three times.
WD-73736 / WD-73835 / WD-73C8
NORMAL LED INDICATIONS
Sta tus LED
La m p LED
Off
Off
Off
Off
Off
Green Blink
Off
Off
Off
Off
ABNORMAL LED INDICATION S
Sta tus LED
La m p LED
Yellow
Off
Blinking
Off
Yellow
Off
Red*
Blinking Red
Off
Red
Off
Page 24
Condition
Off (Standby)
Initialization (40 - 60 seconds) (AC Off)
Lam p cooling (90 seconds after P TV Off)
(Fan is still working)
Power On
Power On Tim er is set
Condition
Tem perature high - room too hot.
Tem perature sensor is disconnected
Lam p cover open.
Lam p Failure - Lamp failed to turn On.
Lamp is broken
Lamp turns Off during P-ON
Fan Stopped
Circuit failure (short)
Disconnected DVI cable, chassis to engine
No LAMP-EN signal from Engine to turn
the lamp On.
Ballast UART com munication problem.

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents