EXTERNAL CONTROL DEVICE SETUP
24. Input select (Command: x b)
(Main Picture Input)
► To select input source for main picture.
Transmission [x][b][ ][Set ID][ ][Data][Cr]
Data Structure
MSB
0
0
0
0
External Input
External Input
0
0
0
0
0
0
0
1
0
0
1
0
0
1
0
0
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
Input Number
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
Ack [b][ ][Set ID][ ][OK/NG][Data][x]
* Real data mapping
00 : Step 0
A :
Step 10 (Set ID 10)
F :
Step 15 (Set ID 15)
10 : Step 16 (Set ID 16)
64 : Step 100
6E : Step 110
73 : Step 115
74 : Step 116
CF : Step 199
FE : Step 254
FF : Step 255
LSB
0
0
0
0
Input Number
Data
DTV
Analogue
AV
Component
RGB
HDMI
Data
Input1
Input2
Input3
Input4
25. 3D(Command: x t) (only 3D models)
(Depending on model)
► To change 3D mode for TV.
Transmission [x][t][ ][Set ID][ ][Data01][ ][Data02]
[ ][Data03][ ][Data04][Cr]
Data Structure
Data01
00 : 3D On
01 : 3D Off
02 : 3D to 2D
03 : 2D to 3D
Data02
00 : Top and Bottom
01 : Side by Side
02 : Check Board
03 : Frame Sequential
Data03
00 : Right to Left
01 : Left to Right
Data04
3D Effect(3D Depth): Min : 00 ~ Max : 14
(*transmit by Hexadecimal code)
*If data1 is 00(3D On), data4 has no meaning.
*If data1 is 01(3D off) or 02(3D to 2D), data2, data3 and
data4 have no meaning.
*If data1 is 03(2D to 3D), data2 and data3 have no
meaning.
Data 1
Data 2
00
O
01
X
02
X
03
X
X : don't care
Ack [t][ ][OK][Data01][Data02][Data03][Data04][x]
[t][ ][NG][Data01][x]
26 . Extended 3D(Command: x v) (only 3D models)
(Depending on model)
► To change 3D option for TV.
Transmission [x][v][ ][Set ID][ ][Data01][ ]
[Data02][Cr]
Data01 : 3D option
00 : 3D Picture Correction
01 : 3D Depth (2D to 3D only)
02 : 3D Viewpoint
03 : 3D Picture Size (Plasma TV only)
04 : 3D Picture Balance (Plasma TV only)
05 : 3D Optimization (Active type (LCD TV) only)
Data02
It has own range for each 3D option deter-
mined by Data01.
1) When Data01 is 00
00 : Right to Left
01 : Left to Right
2) When Data01 is 01, 02
Data
Min: 0 ~ Max: 14(*transmit by Hexadecimal code)
Data value range(0~20) converts Viewpoint range(-
10~10) automatically(Depending on model)
3) When Data01 is 03
00 : Just Scan
01 : 16:9
4) When Data01 is 04
00 : Off
01 : On
5) When Data01 is 05
Data
Min: 0 ~ Max: 02(*transmit by Hexadecimal code)
* Refer to 'Real data mapping'.
Ack [v][ ][OK][Data01][Data02][x][v][ ][NG]
[Data01][x]
Data 3
Data 4
O
X
X
X
X
X
X
O

Hide quick links: