Planning Information
30"
Framed Electric Cooktop
(762)
M O D E L C T 3 0 E
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, cut-out dimensions and
installation specifics.
Wolf recommends using 33" (838) cabinets
with the 30" (762) cooktop.
A Wolf downdraft system, Cooktop or Pro
ventilation hood is recommended. When
installing a ventilation hood, refer to the specific
requirements of the hood for the minimum
dimension to the countertop. Also refer to
Ventilation Recommendations in the Cooktop
Ventilation or Pro Ventilation sections of our
website, wolfappliance.com.
The Wolf 30" (762) framed electric cooktop
requires a separate, grounded 3-wire 240 V AC,
60 Hz, 40 amp or 208 V AC, 60 Hz, 30 amp
service with its own circuit breaker. It has a 4'
(1.2 m) flexible 3-wire conduit for connection at
the electrical supply. Locate electrical within the
shaded area shown in the Installation Specifica-
tions illustration on page 4.
A Wolf 30" (762) or 36" (914) built-in single
oven may be installed below this cooktop. For
this installation, the electrical supply for the
cooktop should be installed in the adjacent
cabinet. Refer to page 6 for additional specifica-
tions. Be aware of the depth of the cooktop
when planning for this installation. The bottom
cabinet support must be able to support 250
lbs (113 kg).
IMPORTANT NOTE: Wolf electric cooktops are
designed and agency approved for installation
with Wolf built-in ovens only.
Dimensions in parentheses are in
millimeters unless otherwise specified.
IMPORTANT NOTE: When a built-in oven is
installed below the cooktop, unless you are
using cabinets deeper than 24" (610), it is
recommended that the electrical supply for the
oven be placed in an adjacent cabinet within
reach of the conduit. A 2" (51) diameter hole to
route the conduit through cabinetry will be
required. Refer to page 6 for location of electri-
cal supply and additional specifications.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
If the 30" (762) framed electric cooktop is to
be used with any combination of additional
cooktop units or modules with a filler strip, the
cut-out width increases to 29" (737). When
multiple cooktop units or modules are installed
side by side, refer to the countertop cut-out
dimensions on page 7.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.
This cooktop is intended for indoor use only.