Samsung SRP-370 User Manual page 32

Thermal receipt printer
Hide thumbs Also See for SRP-370:
Table of Contents

Advertisement

▪ When a=8, the memory switch 8 is set as follows :
Bit
Setting value
1~8
▪ When a=9, the memory switch 9 is set as follows :
Bit
Setting value
2
48
49
3
48
49
4
48
49
5
48
49
6~8
Baud Rate Selection.
MSW9-8
MSW9-7
48
48
48
48
48
49
48
49
49
48
<Function 4> GS ( E pL pH fn a (fn=4)
[Format]
ASCII
GS
(
Hex
1D
28
Decimal
29
40
[Range]
(pL + pH x 256) = 2 (pL=2, pH=0)
fn=4
a=1, 2, 8
[Description]
▪ Transmits the setting value(s) of the memory switch specified by a.
Hexadecimal
Header
37H
Flag
21H
Data
30H or 31H
NUL
00H
▪ Data for the setting is transmitted as 8 bytes or a data string in the order
from bit 8 to bit 1, as follows :
- Off : Hexadecimal = 30H / Decimal = 48
- On : Hexadecimal = 31H / Decimal = 49
Function
Reserved.
Function
Data Length : 8 Bits
Data Length : 7 Bits
Parity : odd
Parity : even
Parity Check : Disable
Parity Check : Enable
Flow Control : DTR/DSR
Flow Control : XON/XOFF
MSW9-6
Baud Rate
48
9600
49
19200
48
38400
49
57600
48
115200
E
pL
pH
fn
a
45
pL
pH
fn
a
69
pL
pH
fn
a
Decimal
Amount of Data
55
1 byte
33
1 byte
48 or 49
8 bytes
0
1 byte
62
<Function 11> GS ( E pL pH fn a d1...dk (fn=11)
[Format]
ASCII
GS
(
Hex
1D
28
Decimal
29
40
[Range]
3 ≤ (pL + pH x 256) ≤ 65535 (0 ≤ pL ≤ 255, 0 ≤ pH 255)
fn=11
1 ≤ a ≤ 4
48 ≤ d ≤ 57
1 ≤ k ≤ 6
[Default]
▪ When a=1 : (d1...dk)="19200"
▪ When a=2 : d=48
▪ When a=3 : d=48
▪ When a=4 : d=56
[Description]
▪ Sets the communication conditions of the serial interface specified by a
according to value d.
a
Communication Condition
1
Baud rate
2
Parity
3
Flow control
4
Data length
- Baud rate setting (d1...dk)
Baud rate
d1
(bps)
2400
50
4800
52
9600
57
19200
49
38400
51
57600
53
115200
49
- Parity setting (d1)
d1
48
49
50
- Flow control setting (d1)
d1
48
49
- Data length setting (d1)
d1
55
56
▪ If the value specified with a, d1 is out of range, this command is ignored.
[Notes]
(The setting is not changed)
▪ This function code fn=11 is enabled only in the user setting mode.
E
pL
pH
fn
a
d1...dk
45
pL
pH
fn
a
d1...dk
69
pL
pH
fn
a
d1...dk
d
k bytes of (d1...dk)
1 byte of (d1)
1 byte of (d1)
1 byte of (d1)
d2
d3
d4
d5
d6
52
48
48
--
--
56
48
48
--
--
54
48
48
--
--
57
50
48
48
--
56
52
48
48
--
55
54
48
48
--
49
53
50
48
48
Parity
No parity
Odd parity
Even parity
Flow control
DTR / DSR
XON / XOFF
Data length
7 bits
8 bits
63