Air Compressor Safety Warnings - Central Pneumatic 67698 Set Up And Operating Instructions Manual

145 psi 5 hp twin cylinder air compressor pump
Hide thumbs Also See for 67698:
Table of Contents

Advertisement

10.
use safety guard for Pulleys.
Compressor Pump Pulley (58), V-belt
(not supplied), and motor pulley (not
supplied) must be covered by a safety
guard (not supplied) covering all moving
elements before operation.
11.
Avoid burns.
Head (6) and Air Outlet components
become very hot during operation. Do
not touch.

Air Compressor safety warnings

1.
Risk of fire or explosion - do not
spray flammable liquid in a confined
area or towards a hot surface. spray
area must be well-ventilated. do not
smoke while spraying or spray where
spark or flame is present. Arcing
parts - keep compressor at least 20
feet away from explosive vapors,
such as when spraying with a spray
gun.
2.
risk of bursting - do not adjust
regulator higher than marked
maximum pressure of attachment.
3.
risk of injury - do not direct air
stream at people or animals.
4.
do not use to supply breathing air.
5.
do not leave compressor unattended
for an extended period while plugged
in. unplug compressor after working.
6.
keep compressor well-ventilated. do
not cover compressor during use.
7.
Drain Compressor Tank daily and after
use. Internal rust causes tank failure
and explosion.
8.
Add correct amount of compressor
oil before first use and every use.
Operating with low or no oil causes
permanent damage and voids warranty.
SKU 67698
The Air
The Cylinder (22), Cylinder
For technical questions, please call 1-800-444-3353.
9.
Do not remove the valve cover or adjust
internal components.
10.
Compressor head gets hot during
operation. Do not touch it or allow
children nearby during or immediately
following operation.
11.
Do not use the air hose to move the
compressor.
12.
Release the pressure in the storage tank
before moving.
13.
The use of accessories or attachments
not recommended by the manufacturer
may result in a risk of injury to persons.
14.
All air line components, including hoses,
pipe, connectors, filters, etc., must be
rated for a minimum working pressure
of 150 PSI, or 150% of the maximum
system pressure, whichever is greater.
15.
USE OF AN EXTENSION CORD IS NOT
RECOMMENDED. If you choose to
use an extension cord, use the following
guidelines:
reCommended minimum wire
gAuge For eXTension Cords
(120 VolT)
nAmePlATe
AmPeres
(at full load)
0 – 6
6.1 – 10
10.1 – 12
12.1 – 16
TAble A
a.
Make sure your extension cord is in
good condition.
b.
Be sure to use an extension cord
which is heavy enough to carry the
current your product will draw. An
undersized cord will cause a drop in line
voltage resulting in loss of power and
eXTension Cord
lengTH
25'
50'
100'
18
16
16
18
16
do not use.
16
16
do not use.
14
12
do not use.