Technical Data - Parkinson Cowan Lyric 55V Operating And Installation Instructions

Gas cooker
Table of Contents

Advertisement

TECHNICAL DATA

DIMENSIONS
Overall
Height to hotplate
Space for fixing at hotplate level
Space for fixing above hotplate level 100mm each side of appliance
Minimum space above grill
Minimum distance from rear wall
Weight of appliance
CONNECTIONS
Gas
Electric
GRILL
Heat Input
Injector Marking
Height
1462mm (nominal)
907mm nominal -
see important note 'Location of the Appliance' (see Page 35).
500mm
20mm
59.3kg
Rear left hand side of appliance at hotplate level
Rc½ (½" B.S.P. female)
220V/240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
Natural Gas
3.0kW (10236 Btu/h)
120
33
Width
554mm
2mm minimum
clearance
L.P.Gas
2.75kW (197.5g/h)
80
Depth
600mm
(from elbow
to front of door panel)
600mm
Nominal