Installation Diagram - Mitsubishi Electric MSY-A24NA Installation Manual

Split-type air conditioners
Hide thumbs Also See for MSY-A24NA:

Advertisement

1-4. iNSTALLATiON DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
1
Installation plate fixing screw
7
(2) 4 x 25 mm
(3) Remote controller holder
1
Fixing screw for (3)
(4) 3.5 x 16 mm (Black)
2
(5) Battery (AAA) for (6)
2
(6) Wireless remote controller
1
Felt tape
(7) (For left or left-rear piping)
1
(8) Air cleaning filter
2
PARTS TO BE PROVIDED
AT YOUR SiTE
(A)
Indoor/outdoor u nit connecting wire*
1
(B)
Extension pipe
1
(C)
Wall hole sleeve
1
(D)
Wall hole cover
1
(E)
Pipe fixing band
2to5
(F)
Fixing screw for (E) 4 × 20 mm
2 to 5
(G)
Piping tape
1
(H)
Putty
1
Drain hose
(I)
(or soft PVC hose, 19/32 in. [15 ram]
1
inner dia. or hard PVC pipe VP16)
(J)
Refrigeration oil
1
(K)
Power supply cord
1
* Note:
Place indoor/outdoor
unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
(8)
r Be sure to use wall hole
sleeve (C) to prevent
indoor/outdoor
connecting
wire (A) from contacting
metal parts in the wall and
to prevent damage by
rodents in case the wall is
hollow.
_[/Wall
hole cover (D)
I
Indoor unit _Seal
the wall hole
1
} [.gapwith putty (H).
Wall hole
FJ_I/ /
,-_
e {CI _l
I
I Fix the pipe to
l
sleev
....
_all
with pipe fixing I
'//"
%
Lband(E).
j
Cat off the
Pipe fixing band
extra length _)
Fixing screw (F)
(1)
h20
in, (500 mm)
(F)
(K)
(A)
,r the leak test, apply insulating mate-
rial tightly so that there is no gap.
race for indoor unit working
Please leave the space as shown in the
picture for maintenance
usage.
_
or more _-_
;
. Installation _ _ t_/'_////_
Ind......
t
plate
_ _ 1_/,
o
/
_ Space
When the piping is to be attached to a
wall containing metals (tin plated) or metal
netting, use a chemically treated wooden
)iece 25/32 in. (20 mm) or thicker between
the wall and the piping or wrap 7 to 8 turns
of insulation vinyl tape around the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump down
before removing the Did air conditioner.
Remake flare according to the dimension
for new refrigerant.
Outdoor
unit installation
Unit: inch
I"
33-1/1B
1g-11/1B
r-@-_Air
inlet
4_.Air outlet_--
4 3/8 x 13/16 slot
1-18/32
Unit: mm
840
_1
500
,
I
42_Air inlet
_
_
CO
cD
CO
ou.e
4-10 x 21 slot
40
I Units should be installed by licensed contractor I