4-WIRE
CONNECTION
iNSTRUCTiONS
Before wiring the range, review the suggested power source location
drawing in Figure 2. If connecting
to a 4-wire electrical system for a
new branch-circuit
or mobile home use a 4-wire connection.
t
Follow
the power
supply
kit manufacturer's
Installation
Instructions
supplied with the strain relief clamp and install.
See Figure 8.
2
Insert the end connectors
for line 1, line 2 and neutral and
tighten securely to the terminal block.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
fidlure or loss of electrical
connection
may
occur if these 3 nuts are loosened or removed.
3
You ml.lst disconnect
the ground strap. Remove the factory
installed ground screw and plate to release the copper ground
strap from the frame of the range. Cut and discard the copper
ground strap and plate. KEEP the ground screw.
4
Connect the green ground wire lead with the eyelet to the frame
of the range with the ground screw using the same hole in the
frame where the ground screw was originally
installed.
See
Figure 9.
5
Make sure all screws are tightened
securely and replace the
rear access cover. See Figure 7.
3-WIRE
CONNECTION
iNSTRUCTiONS
For existing installations
ONLY, refer to Figure 10.
t
Follow
the power
supply
kit manufacturer's
Installation
Instructions
supplied with the strain relief clamp and install.
See Figure 8.
2
Insert the end connectors
for line 1, line 2 and neutral and
tighten securely to the terminal block. See Figure 10.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
fidlure or loss of electrical
connection
may
occur if these 3 nuts are loosened or removed.
3
Make sure all connections
are tightened securely and replace
the rear access cover. See Figure 7.
GROUNDING iNSTRUCTiONS- ONLY 3-WIRE CONNECTIONS:
A ground strap is installed on this range which connects the center
terminal
of the neutral
terminal
block to the range chassis. The
ground strap is connected to the range by the center, lowest screw. See
Figure 10. The ground strap must not be removed unless National,
State or Local Codes do not permit use of a ground strap.
Note: If the ground strap is removed for any" reason, a separate
ground wire must be connected
to the separate ground screw
attached to the range chassis and to an adequate ground source.
iNSTALLATiON
MANUAL
3 & 4-WIRE
PERMANENT
WiRE
CONNECTIONS
3-_ ire permanent
connection
- follo_
steps 1, 2 and 5 belong.
4-wire
permanent
connection
- follow all steps below.
Before wiring the range, review the suggested power source location
drawings
in Figure 2. If connecting
to a 4-wire electrical
system:
t
Follow the manufacturer's
Installation
Instructions
supplied
with the strain relief clamp and install.
2
Strip insulation
away from the ends of the permanent
wiring
for line 1, line 2 and neutral; also strip ground wire on 4-wire
connections. Tighten all 3 or 4-wire leads to the terminal block.
Follow wire locations shown in Figure 11.
DO NOT LOOSEN
the factory installed nut
connections
which
secure the range wiring to the terminal
block. Electrical
failure or loss of electrical
connection
may
occur if these 3 nuts are loosened
or removed.
Note: For 3-wire permanent
connection
skip steps 3 and 4 and
continue with step 5.
3
Disconnect
the ground
strap. Remove the factory installed
ground screw and plate to release the factory installed
copper
ground strap from frame of the range. Cut and discard the
copper strap from the terminal block. KEEP the ground screw,
ground plate and go to step 4.
4
Connect the green ground wire lead to the frame of the range
using the ground screw and plate as shown in Figure 12. Be sure
to install using the same hole in the frame where the ground
screw was originally
installed.
5
Make sure all connections
are tightened
securely and replace
the rear access cover. See Figure 8.
Note: Non-terminated
field wire compression connections
must
be set at approximately
90 in./lbs.
Figure
9
5