If the user of a M-Scope does not follow the operating • Self-diagnostic manual and if the M-Scope is not set up properly, it can allow metal objects to pass • Adaptable to virtually all environments through undetected.
D u c t i o n conTRoL PaneL Fisher Labs is excited to introduce the m-scope™ Portable Walk-Through metal Detector! The m-scope™, the world’s most versatile walk-through metal detector, brings Fisher’s expertise, innovation, and...
If your M-Scope is equipped with the leveling option proceed with step 3, if not, move to step 4. We recommend that bases with the leveler option be used on uneven surfaces.
Page 5
Fisher recommends that all M-Scope units intended for outdoor useage be used with our Weather Protective Package option. This option includes a pop-up shelter that shields the M-Scope from direct sunlight (UV rays), and from rainfall. The 1 LeD “Weather Protected”...
Page 6
There are two types of panels in the M-Scope system. They are called ‘Transmitter’ and ‘Receiver’ panels. Here are several ways in which you can easily tell them apart. Fig. g The LEDs can be controlled manually while in the diagnostics mode by pressing the different numeral keys. Duration is approximately 4.5...
Page 7
Fig. H Fig. H The M-Scope has a Diagnostic Mode that can be used to check the performance of its six Photo Detector base draw latches channels, and of its three separate metal detector zones. It is also useful for exercising all of the system’s various LEDs.
Page 8
BOTTOM ZONE ..= 1.20 To assign a group of settings to one of the User Presets, adjust the all of the M-Scope’s variables as discussed in the preceding instructions, and then press and hold the corresponding numeral key for at least one second to store the settings. This is similar to the way most car radio Presets are stored.
DisasseMbly instructions Editing the access menu is the way to change access codes, and enable or disable the access protection The M-Scope should be powered down (turned off) prior to disassembling the unit, or prior to disconnecting or swapping any feature.
Page 10
When you open the access menu with a Master level code, you can choose between access enabled and wherever there is room for them. The entire M-Scope can be loaded into the back seat of a small car. You may wish to un- access disabled, by pressing the numeral 5 key.
The volume and beep rate are adjustable. To adjust the volume, press the volume key (numeral 1) when the complete expressions for those abbreviations. the M-Scope is in normal operating mode. The unit will start beeping on its own. Use the up/down arrow keys to adjust the volume.
If one or more of the M-Scope’s panels are not ready to detect targets, it could be due to outside aLL DioDes BLocKeD interference. A panel not ready to detect is indicated by the zone indicator LED glowing red, and the Finding Metal targets Without speed Violations ready LEDs on the entrance and exit sides of the M-Scope control panel glowing red.
Need help?
Do you have a question about the M-Scope and is the answer not in the manual?
Questions and answers