INSTALLATION
AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER.
IMPORTANT:
SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable
vapors and liquids in
the vicinity
of this or any other appliance.
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
Cooktop Dimensions
30" Min. *
(76.2 cm)
* 30" (76.2 cm) rain. for
unprotected cabinet and
24" (61 cm) rain. for cabinet
with protected bottom surface.
** Do not obstruct these areas.
Cooktop Cutout Dimensions
D
Air exhaust**
--I
C
Fresh air intake**
4" X 8" (10.2 cmx 20.3 cm)
opening to route armored cable if a
rei eer
Figure 1
I
COOKTOPDIMENSIONS
I
CUTOUT
DIMENSIONS
I
A. WlDTH B. DEPTH
HEIGHT
E.WlDTH
F:DEPTH
G. WlDTH
H. DEPTH
I. HE!GHT I
I
C
D
Min.
MaX:
Min.
Max:
1303A (78.1)121Y2(54.6)1 2 (5.1) I 23A(7) 1 287/8(73.3)I 197/8(50.5)129s/8(75.2)1293A ( 75.6) 1203/8 (51.8) I 20Y2(52.1)
I
4Y2(11.4)
I
All dimensions are stated in inches and (cm).
Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and
allow space for installation of the junction box on the wall at the back of the cooktop.
Printed in United States
P/N 318201430
(0706)
Rev. C