INSTALLATION
INSTRUCTIONS
FOR EXTERNAL EXHAUST
DUCTING
NOTE: If
you
need
to install
ducts,
note
that
the
total
duct
length
of 31/4" x 10" (8.2
x 25.4
cm)
rectangular
or
5" (10.5
cm) diameter/
6" (15.2
cm)
diameter
round
duct
should
not
exceed
120
equivalent
feet
(36.5
m).
Outside
ventilation
requires
a
EXTERNAL
EXHAUST
DUCT.Read
the
following
carefully.
NOTE: It
is important
that
venting
be
installed
using
the
most
direct
route
and
with
as few
elbows
as possible.
This
ensures
clear
venting
of exhaust
and
helps
prevent
blockages.
Also,
make
sure
dampers
swing
freely
and
nothing
is blocking
the
ducts.
Exhaust
connection:
The
exhaust
adaptor
has
been
designed
to mate
with
a standard
31/4" x 10"
(8.2 x
25.4 cm)
rectangular
duct.
If a round
duct
is required,
a rectangular-to-round
transition
adaptor
must
be used.
A 5"(10.5cm)/6"
(15.2cm)
diameter
duct
is acceptable
to use
Maximum
duct length:
For" satisfactory
air" movement,
the
total
duct
length
of
31/4"x 10" (8.2 x 25.4 cm) rectangular
or 5" (10.5 cm)
diameter/6
"(15.2 cm) diameter
round duct should not
exceedl20
equivalent
feet
(36.5
m).
Elbows,
transitions,
wall
and roof
caps,
etc.,
present
additional
resistance
to airflow
and
are
equivalent
to a section
of straight
duct
which
is longer
than
their
actual
physical
size.
When
calculating
the
total
duct
length,
add
the
equivalent
lengths
of all transitions
and
adaptors
plus
the
length
of all straight
duct
sections.
The
chart
below
shows
you
how
to calculate
total
equivalent
ductwork
length
using
the
approximate
feet
of equivalent
length
of some
typical
ducts.
DUCT PIECES
J
@
0
J
Rectangular-to-Round
TransitionAdaptor*
Wall Cap
90° Elbow
45° Elbow
90° Elbow
45° Elbow
RoofCap
StraightDuct6" (15,2cm)
Roundor 31/4 ``x 10"
(8,2x 25,4cm)Rectangular
EQUIVALENT
LENGTH
5 Ft,(1,5m)
40 Ft, (12,2m)
10 Ft, (3 m)
5 Ft,(1,5m)
25 Ft, (7,6m)
5 Ft,(1,5m)
24 Ft, (7,3m)
1 Ft,(0,3m)
NUMBER
x
USED
x
()
x
()
x
()
x
()
x
()
x
()
x
()
x
()
Total
Ductwork
EQUIVALENT
LENGTH
Ft,or m
Ft,or m
Ft,or m
Ft,or m
Ft,or m
Ft,or m
Ft,or m
Ft,or m
Ft. or m
* IMPORTANT:
If a rectangular
to round transition
adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, in order
to allow free movement
of the damper.
Equivalent
lengths
of duct
pieces
are
based
on actual
tests
and
reflect
requirements
tot good
venting
pertbrmance
with
any vent
hood.