PRE-INSTALLATION
REQUIREMENTS
Tools Required
for Installation:
1. Phillips screwdriver
2.
10 mm socketwith
ratchet.
3.
Channeldock adjustable pliers.
4.
Carpenter's level.
absence of local codes, with tile National Electrical
Codes, ANS!/NFPA 70 (latest edition). If in doubt,
call a licensed electrician. DO NOTcut off or alter
the grounding prong on the power supply cord. In
situations where a two-slot receptacle is present,
it is tile owner's responsibility to have a licensed
electrician replace it with a properly
grounded
three prong grounding type receptacle.
ELECTRICAL
REQUIREMENTS
CIRCUIT-Individual,
properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY- 2 wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
NOTE: Because of
potential inconsistent voltage capabilities, the use of this
washer with power created by gas powered generators,
solar powered generators, wind powered generators or
any other generator other than the local utility company
is not recommended.
OUTLET RECEPTACLE- Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
NOTE: GFI (Ground Fault Interrupter) receptacle is not
required.
GROUNDING
REQUIREMENTS
Improper connection of the equipment
grounding conductor (:an result in a risk of electrical
shock. Check with a licensed electrician if you are in
doubt asto whether the appliance is properly grounded.
.
Tile washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
.
Since your washer is equipped with a power supply
cord having an equipment-grounding
conductor
and a grounding plug, tile plug MUSTbe plugged
into an appropriate, copper wired receptacle that
is properly installed and grounded in accordance
with all local codes and ordinances or in tile
WATER
SUPPLY
REQUIREMENTS
Hot and cold water faucets MUST be installed within
42 inches (!07 cm) of your washer's water inlet. Tile
faucets MUST be 3/4 inch (1.9 cm) garden hose type
so inlet hoses (:an be connected. Water pressure MUST
be between 30 and 120 pounds per squareinch (maximum
unbalance pressure, hot vs. cold, 10 psi.) "four water
department (:anadvise you of your water pressure.The hot
water temperature shouldbe about 140 degreesF(60 degrees
C).
DRAIN
REQUIREMENTS
1.
Drain capable of eliminating 17 gals (64.3 L) per
minute.
2.
A standpipe
diameter
of I-I/4
in. (3.18 cm)
minimum.
3.
The standpipe height above the floor should be:
Minimum height:
24 in. (61 cm)
Maximum height:
96 in. (244cm)
o
O0
BACK
T
96 in.
(244 cm)
Max.
24 in.
(61 cm)
MJn,
NOTE:
Drain hose attached to the washer can reach a gO
in. (229 cm) high standpipe. For higher standpipe,
use hose P/N 134369410,
available
from
an
authorized parts distributor.