Frigidaire PL36DD Installation Instructions Manual
Frigidaire PL36DD Installation Instructions Manual

Frigidaire PL36DD Installation Instructions Manual

Downdraft blower system
Hide thumbs Also See for PL36DD:

Advertisement

MODELSPL30DD& PL36DD
DOWNDRAFTBLOWERSYSTEM
INTENDED FOR DOMESTIC COOKHNG ONLY
TO REDUCE
THE
RISK
OF FmRE, ELECTRIC
SHOCK,
OR
INJURY
TO PERSONS,
OBSERVE
THE FOLLOWmNG:
1. Use this unit only in the manner
intended
by the manufacturer.
If you have questions,
contact
the manufacturer
at the address
or telephone
number
in the warranty.
2.
Before
servicing
or cleaning
unit, switch
power
off at service
panel
and lock the service
disconnecting
means
to prevent
power from being switched
on accidentally.
When the service
disconnecting
means
cannot
be locked,
securely
fasten
a
prominent
warning
device,
such as a tag, to the service
panel.
3.
Installation
work
and electrical
wiring
must
be done
by a
qualified
person(s)
in accordance
with all applicable
codes
and standards,
including
fire-rated
construction
codes
and
standards.
4.
Sufficient
air is needed
for proper
combustion
and exhausting
of gases through
the flue (chimney)
of fue! burning
equipment
to
prevent
backdrafting.
Follow
the
heating
equipment
manufacturer's
guideline
and safety standards
such as those
published
by the National
Fire Protection
Association
(NFPA),
and the American
Society
for Heating,
Refrigeration
and Air
Conditioning
Engineers
(ASHRAE),
and the local
code
au-
thorities.
5. When
cutting
or drilling
into wall
or ceiling,
do not damage
electrical
wiring
and other hidden
utilities.
6.
Do not use this range
hood with an additional
speed
control
device.
7.
Ducted
fans must always
be vented
to the outdoors.
8. To reduce
the risk of fire, use only metal ductwork.
9.
Do not instal! this product
with
the activating
switch
directly
behind
a burner
or element.
Minimum
distance
between
the
switch
and the edge of the burner
should
be 4 inches.
10. Loose-fitting
or hanging
clothing
should
never be worn when
operating
this appliance.
They
may
be ignited
by burners/
elements
on cooktop.
11. Children
should
not be left alone
or unattended
in the area
where
this appliance
is in use.
12. When flaming
foods, turn the blower
OFF. An operating
blower
may spread
the flames.
13. This unit must be grounded.
TO REDUCE
THE RmSK OF A RANGE
TOP GREASE
FIRE:
1. Never leave surface units unattended
at high settings.
Boilovers
cause
smoking
and greasy
spillovers
that may ignite.
Heat
oils slowly
on low or medium
settings.
2. Always
turn hood
ON when
cooking
at high
heat
or when
cooking
flaming
foods.
3.
Clean ventilating
fans frequently
Grease sh°uld
n°t be all°wed
to accumulate
on fan or filter.
4.
Use proper
pan size. Always
use cookware
appropriate
for
the size of the surface
element.
TO REDUCE
THE
RISK
OF INJURY
TO PERSONS
IN THE
EVENT
OF A RANGE
TOP
GREASE
F_RE, OBSERVE
THE
FOLLOWINGa:
1. SMOTHER
FLAMES
with a close-fitting
lid, cookie
sheet,
or metal tray, then turn off the burner.
BE CAREFUL
TO
PREVENT
BURNS.
If the flames
do not go out immedi
ately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2.
NEVER
PICK UPA
FLAMING
PAN -You
may be burned.
3.
DO NOT USE WATER,
including
wet dishcloths
or towels
- a violent
steam
explosion
will result.
4.
Use an extinguisher
ONLY
if:
A. You know you have a Class ABC extinguisher,
and you
already
know
how to operate
it.
B. The fire is small
and contained
in the area where
it
started.
C. The fire department
is being
called.
D. You can fight the fire with your
back to an exit.
a Based
on "Kitchen
Firesafety
Tips" published
by NFPA.
1. For
general
ventilating
use
only.
Do not
use
to exhaust
hazardous
or explosive
materials
and vapors.
2. To avoid motor bearing
damage
and noisy and/or unbalanced
impellers,
keep drywall spray, construction
dust, etc. off power
unit.
3. Clean
filters and greaseqaden
surfaces
frequently.
4.
Do not repair
or replace
any part of this
appliance
unless
specifically
recommended
in this manual.
All other servicing
should
be done
by a qualified
technician.
5.
Please
read specification
label on product
for further
informa-
tion and requirements.
PLANNING
This downdraft
blower
system
is
designed
to be used to exhaust
COUNTER
airborne
contaminants
when
TOP
COOK TOP
cooking
with
a variety
of gas or
electric
cooktops.
It can
be
mounted
in island,
peninsula,
or
conventional
wall locations.
This unit can be easily
installed
following
these
basic steps:
Cut out the countertop
opening.
Mount
the unit in the
cabinet.
Connect
the ductwork
and electrical.
Install the cooktop.
TYPICAL
INSTALLATION
CHIMNEY
TOP
L
/
/
3-1/4" x 10"
DUCT CONNECTOR
INSTALLER:
Save this manual
for Electrical
Inspector
and Homeowner
to use.
HOMEOWNER:
Use and Care Information
on Page 5.

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire PL36DD

  • Page 1 MODELSPL30DD& PL36DD DOWNDRAFTBLOWERSYSTEM INTENDED FOR DOMESTIC COOKHNG ONLY TO REDUCE RISK OF INJURY TO PERSONS IN THE TO REDUCE RISK OF FmRE, ELECTRIC SHOCK, EVENT OF A RANGE GREASE F_RE, OBSERVE INJURY TO PERSONS, OBSERVE THE FOLLOWmNG: FOLLOWINGa: 1. Use this unit only in the manner intended by the manufacturer.
  • Page 2: Take Measurements

    DIRECTION" cooktop, countertop cut-out, and cabinet requirements. Model PL30DD will fit in most 30" wide cabinets and the Model page 3, if necessary. PL36DD will fit in most 36" wide cabinets. However, it is recommended that oversized cabinets be used for easier instal- 6"ROUND...
  • Page 3: Mount The Unit

    CUT COUNTER, TOP OPENMNG 1. Lay out and cut the cooktop cut-out far enough FORWARD CHANGING BLOWER Dm$CHARGE (Optionam) downdraft will fit behind 2. Set cooktop in place and slide it as far forward as possible. The blower is shipped with its discharge facing DOWN.
  • Page 4: Install Ductwork

    INSTALL DUCTWORK WIRING DIAGRAM 120 VAC CAUTBON - BEFORE CUTTING HOLE IN CABINET FOR DUCT- MNE _N WORK." Check for interference with floor joists, wal! studs, electri- cal wiring or plumbing. 3-1/4" X 10" TO 6" RD TRANSmON 6" RD ELBOW &...
  • Page 5 USE AND CARE USE AND CARE - JContinued} Always turn the downdraft blower on before you begin cooking establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off.
  • Page 6: Service Parts

    SERVICE PARTS Models PL30DD & PL36DD Downdraft Blower System KEY NO. DESCRIPTION QTY. Bushing, 7/8" Bushing, Split Heyco, 5/8" Bushing, Heyco, 1/2" Roller Switch Assembly, Up/Down Wire Harness, Speed Control Nut, 3/8-32 Knob Motor insolator Lower Switch Bracket Assembly Green Ground Wire...
  • Page 7 SERVICE PARTS Models PL30DD & PL36DD Downdraft Blower System...
  • Page 8 Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained...

This manual is also suitable for:

Pl30dd

Table of Contents