Download Print this page

Frigidaire FGB24L2ECD Installation Instructions Manual page 6

Hide thumbs Also See for FGB24L2ECD:

Advertisement

Available languages

Available languages

8. Connection
to gas
A. Model with 1 1/2oven cavity (seefigure 9)
Pressure Regulator
3/8" Nipple//_
Adaptor or Union /
_
Solid Pipe Or Flex _--_
Connector
_<_
External Shut-Off Valve ---,_L_oo_
Figure 9
[f flexible
gas connector
is used,
gas line
must
be A.G.A.
design
certified.
B. Model
with
2 oven cavities
(seefigure 10)
Oven Safety
Valve
Pilot Adjustment
(If Equipped)
Pressure Regulator
Shut Off Valve
Support Bracket
Adaptor or Union
Shut Off Valve
External Shut Off Valve *
Figure 10
IMPORTANT:
Prior to attaching gas piping to the oven,
move the shut-off valve support bracket to the left as far
as possible and tighten its mounting screw from
underneath the oven. This keeps the safety valve/
pressure regulator assembly from moving.
BEFORE CONNECTING THE UNIT
Remove all packing material and literature from wall
oven before connecting gas and electrical supply to the
appliance.
If applicable, remove broiler or storage drawer by pulling
drawer out to stops. Lift drawer front to clear stops and
pull out.
Leak testing
of the appliance shall be conducted
according to the manufacturer's
instructions.
Check forteaks.
After connecting gas, check system
for leaks with a manometer.
If a manometer is not
available shut all pilots off, turn the gas supply on the
unit and use a liquid leak detector at all joints and
connections.
Tighten
all connections
if necessary to prevent gas
leakage in the wall oven or supply line.
IMPORTANT:
A pipe joint sealant resistant to the action
of LP Gas must be used on all pipe connections.
Do not use a flame to check for leaks
from gas connections.
Checking for leaks withaflame
may result in a fire or explosion.
Disconnect
the oven and its individual
shutoff
valve
from the gas supply piping system during any pressure
test greater than Y2 psig.
Isolate the wail oven from the gas supply
piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than Y2psig.
9. LPiPropane
Gas Conversion
A, Pressure
Regulator
Conversion
Note:
Do not remove the Pressure Regulator.
Convert
the Pressure Regulator
for use with LP Gas
(see figure
11)
If applicable, remove broiler or storage drawer by
pulling drawer out to stops. Lift drawer front to clear
stops and pull out.
Locate pressure regulator on lower back wall and
convert as shown in figure 1I.
A, Remove the cap from tile pressure regulator.
B, Remove the plunger,
C.Turn tile plunger upside down with the enlarge end
TOWARDS regulator,
D. Replace the plunger inside the regulator.
The
letters LP or 10" W.C. should be visible on tile
exposed end of the plunger.
E. Replace the cap on the pressure regulator.
NOTE: Tile type of gas pressure the regulator is set for
is indicated on the top of tile plunger.

Advertisement