System Requirements; Wire System - Frigidaire GLGQ2170KE0 Installation Instructions Manual

Gas & electric dryer
Table of Contents

Advertisement

Available languages

Available languages

Electrical
System
Requirements
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen-
erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not
recommended.
Electrical
requirements
for electric
dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY- 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through
the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes do not permit grounding through the neutral.
OUTLETRECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire
receptacle
(NEMA
type
10-30R)
The dryer MUST employ a 3-conductor power supply cord
NEMA 10-30 type SRDTrated at 240 volt AC minimum,
30 amp, with 3 open end spade lug connectors with
upturned ends or closed loop connectors and marked
for use with clothes dryers. For 3-wire cord connection
instructions see ELECTRICALCONNECTIONS FOR A
3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
4-wire
receptacle
(NEMA
type
14-30R)
The dryer MUST employ a 4-conductor power supply cord
NEMA 14-30 type SRDTor ST(as required) rated at 240
volt AC minimum, 30 amp, with 4 open end spade lug
connectors with upturned ends or closed loop connectors
and marked for use with clothes dryers. For 4-wire cord
connection instructions see ELECTRICALCONNECTIONS
FORA 4-WIRE SYSTEM.
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).
Electrical
requirements
for gas dryer
CIRCUIT - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse or
circuit breaker.
POWER SUPPLY- 2-wire, with ground, 120 volt, single phase,
60 Hz, Alternating Current.
POWER SUPPLYCORD - The dryer is equipped with a 120 volt
3-wire power cord.
GROUNDING CONNECTION - See "Grounding requirements"
in Electrical Installation section.
Do not, under
"_
any circumstances,
]
cut, remove,
or bypassthe
,_grounding
prong.
_,
Power cord with
3-prong grounded plug

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glgq2170ks0

Table of Contents