Location Of Your Dryer - Frigidaire AGQ6000CES1 Installation Instructions Manual

Gas & electric dryer
Table of Contents

Advertisement

Available languages

Available languages

_JNCORRECT
INSTALL
MALE F ITTINGS
INCORRECT
DIRECTION
Ininstallations
where t heexhaust system i snotdescribed
intilecharts,
the following method must beused t odetermine
iftheexhaust
system i s
acceptable:
I. Connect
aninclined ordigital manometer
between
thedryer arid the
point theexhaust connects
tothedryer,
2. Set t he dryer timer and temperature
toairfluff(cool down) and start
thedryer
3. Read themeasurement
onthemanometer
4. The system b ack p ressure
MUST NOT be higher than 0.75 inches of
water column,
if the system back pressure is less than 0.75 inches
of water column, the system is acceptabb.
If the manometer
reading
is higher than 0,75 inches of water column, the system is too
restrictive and the installation
is unacceptable,
Although
vertical orientation
of the exhaust system is acceptable, certain
extenuating
circumstances could affect the performance
of the dryer:
Only the rigid metal duct work should be used.
Venting vertical through
a roof may expose the exhaust system
to down drafts causing an increase in vent restriction.
Running the exhaust system through
an u/finsulated area may
cause condensation
and faster accumulation
of lint.
Compression or crimping of the exhaust system will cause an
increase in vent restriction.
The exhaust system should be inspected and cleaned a minimum of
every
I8 months
with normal usage. The more the dryer is used, the
more often you should check the exhaust system and vent hood for
proper operation,
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting.
Howevel, on electric dryers, exhausting can be to the right or left side of
the cabinet or the bottom of the dryer. On gas dryers, exhausting can be
to the right side of the cabinet or the bottom of the dryer. Directional
exhausting can be accomplished
by installing Exhaust Kit, P/N
131456800,
available through your parts distributor.
Follow the
instructions supplied with the kit.
EXHAUST
DUCT LOCATtNG
DiMENSiONS
/_ SAME AS OTHER SIDI:
5 7/8"
/
4 318"
13 I/2"
7
The dryer MUST be isolated from the gas supply piping system
during
any pressure testing
of the gas supply piping system at test
pressures equal to or less than
I/2 psig (345
kPa),
LOCATION OF YOUR DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather conditions.
2, In an area where it will come in contact with curtains, drapes, or
anything that will obstruct the flow of combustion and ventilation air,
3, On carpet, Floor MUST be solid with a maximum slope of 1 inch (2.54
cm).
iNSTALLATION
IN RECESS OR CLOSET
1, A dryer instalk_d in a bedroom,
bathroom,
recess or closet, MUST be
exhausted
outdoors.
2, No other fuel burning appliance shall be installed in the same closet
as the Gas dryer.
:L Your dryer needs the space around it for proper ventilation.
DO NOT instafl
your dryer in a closet with
a sofid door.
4, A minimum of 120 square inches (774,2 square cm) of opening,
equally divided at the top and bottom of the door, is required. Air
openings are required to be unobstructed
when a door is installed. A
Iouvered door with equivalent air openings for the full length of the
door is acceptable.
MINIMUM
INSTALLATION
CLEARANCES
- Inches
(cm)
SIDES
REAR
TOP
FRONT
Alcov:_
0(0:m)
0(0:m)
0(0:m)
Closet
0 (0 cm)
0 (0 cm)
0 (0 cm)
I (2.54 cm)
Closet door ventilation
required:
2 Iouvered openings each 60 square,
inches (38-7 square centimeters) -- 3 inches (7,6 cm) from bottom
and
top of door,
This dryer
MUST
be exhausted
outdoors,
5
The following
illustrations
show minimum
clearance dimensions for
proper operation
in a recess or closet installation,
GAS SUPPLY
REQUIREMENTS
_Replace
copper
connecting
pipe
that
is not
plastic-coated,
Stainless
steel
or plastic-coated
brass
MUST be
used,
1. Installation
MUST corfform with local codes, or in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223,I
(latest
edition).
2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.
if codes allow, flexible metal tubing
may be used to connect your
dryer to the gas supply line. The tubing MUST be constructed
of
stainless
steel or plastic-coated
brass.
4. The gas supply line MUST }lave an individual
shutoff
valve,
5. A I/8 inch (0.32 cm) N,RT, plugged tapping,
accessible for test
gauge connection,
MUST be installed immediately
upstream of the
gas supply connection
to the dryer.
6. The dryer MUST be disconnected
from the gas supply piping
system during
any pressure testing
of the gas supply piping system
at test pressures in excess of I/2 psig (3.45
kPa).