Exhaust Information (cont.)
Insulation
• I)uclwork which runs through
an unheated
area or is near an air-conditioning
duct should be insulated
to reduce
condensation
and lint buildup.
Parts Available
From Local Service
Organization
• Rigid Metal Duct Components
WX8X64
100
IllIll
(4")
x
60
('Ill
(2')
Duct
WX8XS1
100 mm (4")Elbow
WX8X88
100 mm (4") Aluminum
Hood
WE25X28
Exhaust Deflector
• Flexible Metal Duct Components
Kit WX8X75
2.1 m (7') Aluminum
Flexible
Duct
10/! mm
(4") (lamps
(2)
100 mm
(4") Aluminum
Hood
Inside Exhausting
BEDROOM,
BATHROOM,
ALCOVE, OR CLOSET INSTALLATIONS
MUST BE EXHAUSTED
TO THE OUTDOORS.
EXHAUSTING
TO THE OUTDOORS
IS STRONGLY
RECOMMENDED.
EXHAUSTING
INDOORS
MAY CAUSE
LINT ACCUMULATION
AND MOISTURE
DAMAGE
INCLUDING
MOLD AND MILDEW.
If the installation
makes it impossible
to exhaust
to the
outdoors,
a 10/! mm (4") exhaust deflector
(WE25X28)
and 600 mm (2') rigid metal duct (WX8X64) must be installed
over exhaust
duct. A clearance
of 200 mm (8") is required
be/ween rear of (hyer and the wall, and the deflector
should be pointing
up.
600 mm (24") RIGID
ORFLEXIBLEDUCT
EXHAUSTDEFLECTOR
(WE25X28)
Special Installation Requirements
Alcove or Closet Installation
• If your (hTer is approved
fi)r installation
in an alcove or ( loset it will be stated on a label on the (hTer back.
• Tile (hyer must be exhausted
to the outdoors.
• Minimum
clearances
between &yet cabinet and adjacent
walls or other combustible
smtitces are:
0 mm clearance
on either side
80 mm (3") t]ont and rear
• Minimum
vertical space flom floor to overhead
cabinets,
ceilings, etc. is 1.3 m (52").
• Closet doors must be louvered
or otherwise ventilated
and must contain at least 400 cm _ (60 square inches) open area
equally distributed.
If this closet contains both a washer and a duet,
doors must contain 800 cm _ (120 square inches)
of open space equally distributed.
SERVICING:
-_ CAUTION:
Consideration must be given to provide adequate clearances
for installation and servicing.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation
(verify proper operation after servicing/installation).