Instructi
Electric
49
ryer
or Visit our Web site at: www.GEAppliances.com
(US)
BEFORE YOU BEGIN
Read
these
instructions
completely
and carefully.
•IMPORTANT
- Save these
instructions for local inspector's
use,
•IMPORTANT
- Observe
all
governing
codes and ordinances.
• Note to Installer
- Be sure to leave these instructions
with
the customer.
• Note to Customer
- Keep these instructions
with your Use
and Care Book for filture reference.
• Exhausting
the dryer to the outdoors is strongly recom-
mended
to prevent large amounts
of moisture from being
blown into the room.
• Before the old dryer is removed
from service or discarded,
remove the dryer door.
• Service information
and the wiring diagram are located in
the control console.
• Do not allow children on or in the appliance. Close
supervision
of children is necessary when the appliance is
used near children.
FORYOUR SAFETY:
WARNING
• Use only rigid metal or flexible metal 4-in. diameter
ducVwork for exhausting to the outdoors. Never
use plastic or other combustible,
easy-to-puncture
ductwork.
• This appliance
must be properly
grounded
and installed
as described
in these instructions.
• Do not install or store appliance
in an area where it
will be exposed to water and/or weather
• Install the dryer where the temperature
is above 50°F
for satisfactory operation
of the dryer control system.
NOTE: InstaRation
and service
of this dryer
requires
basic mechanical
and electrical
skills.
it is your
responsibility
to contact
a qualified
installer
to make the electrical
connections.
TOOLS YOU
WiLL NEED
SLIP JOINT PLIERS
[_
FLAT B LADE SCREWDRIVER
PHILLIPS
SCREWDRIVER
%
MATERIALS YOU WiLL NEED
4"DIA, METAL DUCT
4"
(RECOMMENDED) DUCT
CLAMPS (2)
OR
4"SPRING
CLAMPS (2)
4"DIA, F LEXIBLE
METAL DUCT _
(IF NEEDED)
%
4"DIA, METAL
ELBOW
DUCT TAPE
EXHAUST HOOD SAFETY G LASSES
_
3/4" STF_N RELIEF
GLOVES ULRECOGNIZED
DRYER POWER
CORD K IT
(NOT PROVIDED
WITH DRYER)
UL RATED 120/240V,
30A
WITH 3 OR 4PRONGS,
IDENTIFY
THE PLUG T YPE
ASPER THE HOUSE
RECEPTACLE
BEFORE
PURCHASING
LINE CORD.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Prepare
the Area and Exhaust for Installation
of
New Dryer (see section 1).
Check and Ensure the Existing External Exhaust is
Clean (see section 1) and Meets Attached
Installation
Specifications
(see section 3).
Remove the Foam Shipping Pads (see section 1).
Move the Dryer to the Desired Location.
Connect the Power Supply (see section 2).
Connect the External Exhaust (see section 4).
Level Your Dryer (see section 5).
Step 8
Step 9
Check tile Operation
of the Power Supply
and Venting.
Place the Owners Manual and tile Installation
Instructions
in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation,
see section 6.
For Bathroom
or Bedroom
Installation,
see section 7.
For Mobile or Manufactured
Home see, section 8.
For side or bottom exhaust, see section 9.

Advertisement

loading

Summary of Contents for GE DLLSR33EF5WC

  • Page 1 Electric Installatio ryer Instructi or Visit our Web site at: www.GEAppliances.com (US) BEFORE YOU BEGIN FORYOUR SAFETY: Read these instructions completely and carefully. WARNING •IMPORTANT - Save these instructions for local inspector's use, • Use only rigid metal or flexible metal 4-in. diameter •IMPORTANT - Observe ducVwork for exhausting to the outdoors.
  • Page 2: Installation Instructions

    Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for installation and service. [] PREPARING FOR INSTALLATION [] ELECTRICAL CONNECTION OF NEW DRYER...
  • Page 3: Installation

    Installation instructions L Turn off the circuit breaker (s) (30 amp) or remove the dryer's [] EXHAUST iNFORMATiON circuit fl_se at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. ,_WARNING - USE ONLY METAL 4-IN. DUCT. 3.
  • Page 4 Installation Instructions [] EXHAUST CONNECTION STANDARD REAR EXHAUST (Vented above floor level) _I_WARNING - TO REDUCE RISK OF FIRE OR PERSONAL INJURY: ELBOW HIGHLY • Exhausting the dryer to the outdoors is strongly recom- RECOMMENDED mended to prevent large amounts of moisture from being...
  • Page 5 Installation Instructions, Indoor Exhausting INDOOR EXHAUSTING USING FLEXIBLE METAL DUCTS If rigid all-metal duct cannot be used, then flexible all-metal ducting NOTE: MOBILE HOME, BEDROOM, BATHROOM, can be used, but it will reduce the maxinmm recommended duct ALCOVE OR CLOSET INSTALLATIONS [ength.
  • Page 6 Installation nstructions: ADDING NEW DUCT [] DRYER EXHAUST TO RIGHT OR BOTFOM CABINET FIXING HOLE WARNING - BEFORE PERFORMING PORTION "A" THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. PROTECT YOUR HANDS AN DAR MS FROM S HARP EDGES WHEN WORKING INSIDE...
  • Page 7 installation instructions [_] CHANGING DIRECTION ADDING ELBOW FOR EXHAUST DOOR OPENING THROUGH BOTTOM OF CABINET 1. Open the door and remove the flier plugs opposite • Insert the elbow through the rear opening and connect it to hinges. With the door completely open, remove the the dryer internal duct.
  • Page 8 Notes...

This manual is also suitable for: