Consult with your local building code agency and insurance
representative before you begin your installation to ensure
compliance with local codes, including the need for permits
and follow-up inspections.
Several issues must be addressed when selecting a suitable
location for your Advance Pellet Stove. Observing required
clearances to combustible materials, the proximity to a safe
chimney or venting system, and the accessibility of electrical
supply must all be considered. In addition, selecting a location
that takes advantage of the building's natural air flow is also
desirable to maximize the heating effectiveness of the heater.
In many cases, this is a central location within the building.
Place the stove on a noncombustible floor or a floor protector
that extends 6" (152mm) to the front, 6" (152mm) to the sides
and 1" (25mm) to the rear of the stove. In the US, the front
and side floor protection is measured from the door opening.
In Canada, the measurements are from the appliance. (Fig. 8.)
Floor protection must be placed under any horizontal venting.
This protection must extend a minimum of 2" (51mm) beyond
each side of the pipe.
In Canada, you may follow smaller U.S. floor protection
requirements ONlY if the user agrees to completely
shut-down the appliance, and allow it to cool to where all
fire is extinguished and the combustion blower and its
indicator light shuts off, prior to opening the firebox door
or ash door.
Place the stove away from combustible walls at least as far as
shown in figures 6, and 7. The clearance to a ceiling above the
appliance is 24" (608mm).
Note that the clearances shown are minimum for safety, but
do not leave much room for access when cleaning or servicing.
Please take this into account when placing the stove.
mobile home Installation
When installing this stove in a mobile home several
requirements must be followed:
1. The unit must be bolted to the floor. This can be done with
1/4" lag screws through the 2 holes in the base plate shown
in Fig. 11, Page 10.
2. The unit must also be connected to outside air. See page 14.
3. Floor protection and clearances must be followed as shown.
4. Unit must be grounded to the metal frame of the mobile
home.
5. WARNING - DO NOT INSTALL IN A SLEEPING ROOM.
CAuTION: This appliance must be vented to the outside.
The factory-built chimney must conform to CAN/ULC-S629,
Standard for 650°C Factory-Built Chimneys. Use the vent or
chimney manufacturer's components to provide an effective
vapor barrier where the vent penetrates to the exterior.
The top section(s) of chimney must be removable to a maximum
height of 13' (3.9 M) to allow transport.
Installation and repair of this stove should be done by a
qualified service person. The appliance should be inspected
before use and at least annually by a qualified service person.
Frequent cleaning will be required. It is imperative that control
compartments, burners, and circulating air passageways of
the stove be kept clean.
9

Installation

Alternate floor protector
dimension may be used
as long as they satisfy the
measurement requirements
shown below.
M i n u m u m s i z e f l o o r
protection for a corner
installation hearth pad is
36" x 36".
1"
25mm
Floor Protection
Fig. 7
The Clearance to The Top of The Unit is 60" (152cm)
Measured From The Floor.
Floor Protection
requirements
j
K
l
NOTE:
Measurement
"K" is measured
from the glass
in the US ONLY
T h E S T r u C T u r A l I N T E g r I T Y O F T h E
mANuFACTurEd hOmE FlOOr, wAll, ANd
CEIlINg/rOOF muST bE mAINTAINEd.
hOT whIlE IN OPErATION.
KEEP ChIldrEN, ClOThINg, ANd FurNITurE AwAY.
CONTACT mAY CAuSE SKIN burNS.
7" / 178mm
10"
254mm
US
Sides
6"
6"
Front
Rear
1"
j
uSA
K
Floor Protection
Minimum hearth pad is 38-5/8" x 27-3/4.
!
CAUTION
Fig. 6
Canada
200mm
450mm
200mm
l
j
Canada
1-90-09730R29_02/14

Advertisement

Table of Contents
loading

Table of Contents