Download Print this page

Bosch NGT73 Installation Instructions Manual page 3

Steel gas cooktops with full-surface grates 30"/36" models
Hide thumbs Also See for NGT73:

Advertisement

INSTALLING
THE COOKTOP
I. Seal the Cool(top
Apply the foam tape packaged with
the cooktop
to underside
of
the cooktop
along the perimeter
before
installing.
See Fig. 3.
Important:
For solid surface material
installations
such as Surel
TM
and Corian ®, consult
with
solid surface
manufacturer.Apply
heat
reflective
tape such as Scotch®Aluminum
Foil Tape
#425 or #427
around
the cutout
so that it folds over on the top and sides. DO
NOTWRAPTHETAPE
UNDERNEATH
THE COOKTOR
Be sure
the tape extends
beyond
the outermost
flange of the cooktop.All
corners
should be covered with tape. See Fig 3.
2. Attach
Brackets
to the
Cool(top
Attach
clamps of the hold-down
brackets
packaged with the cool(-
top to the rough-in
box. Use the washers and screws provided.
See
Fig. 4.
3. Install
the Cool(top
Insert
cool<top
into the cutout.Adjust
hold-down
brackets
to de-
sired position
and tighten
screws to rough-in
box. Insert adjusting
screw into clamp and secure cooktop
to countertop.
See Fig. 4.
Important:
For solid surface material
installations,
insert a wooden
block between
the end of the screw and the bottom
of the coun-
tertop.
Do not overtighten
adjusting
screw. See Figure 4.Trim
ex-
cess aluminum
tape around
cooktop
flange.
4. Connect
Gas Supply
The gas inlet to the unit is located at the right rear of rough-in
box.
See Figure 5.After
installing a gas shut-off
valve in an easily acces-
sible location
under
the unit
(see Figure 6), install the pressure
regulator
(supplied)
to manifold
pipe usingTeflon ® tape on threads
of manifold
pipe.To
prevent
possible
damage to the gas pressure
regulator,
install it after the rough-in
box is in its permanent
posi-
tion.
CAUTION:
Do not attempt
any adjustment
of the pressure
regu-
lator, except for conversion
to propane.
Connect
the gas supply line to the unit pressure
regulator
using a
I/2" flex gas line connector
between
wall shut-off
valve and pres-
sure regulator.
(See complete
procedure
in Figure 6.)
Continued
next
page
Figure
3
Counter
cutout
-
solid surface
countertops
:' !_
A
L.._jA
_':_ i_
Cutout
shows
location
of Aluminum
Reflective
Tape
Heat Reflective
Tape
_
:2,.:__
Section
'A - A"
Figure
4
Attaching
hold-down
brackets
'
i
_,_Adjusting
Screw
" _
Figure
5
Rough-in
Box area.
Opening
for Gas
Connection
&
Electrical Cord
)Ct_ulout
for 30" models - 12-5/8"
for 36" models - t2-1/2"
Figure
6
Gas and electrical
location.
..g"
L
Gas Slubeut
1/2" Female
. Pipe Threads
-Supply Cord
120V
PLof Wall
Receptacle
PAGE 3

Advertisement

loading

This manual is also suitable for:

Ngt93Ngp73Ngp93