Table Of Contents - North Road Technologies Geyser 6000–3.0 Installation & Owner's Manual

Heat pump water heater
Table of Contents

Advertisement

Contents
SAFETY INFORMATION-------------------------------------------------------------------------2
Please Keep These Instructions For Reference -----------------------------------------3
GEYSER 6000-3.0™--------------------------------------------------------------------------5
Technical Specifications -------------------------------------------------------------------5
Features: -------------------------------------------------------------------------------------5
Unit Specifications: -------------------------------------------------------------------------5
Grounding instructions-----------------------------------------------------------------------6
SYSTEM REQUIREMENTS -------------------------------------------------------------------6
INSTALLATION--------------------------------------------------------------------------------6
SECTION 1-General----------------------------------------------------------------------------6
SECTION 2-Location---------------------------------------------------------------------------8
SECTION 3-Plumbing ------------------------------------------------------------------------8
SECTION 4-Electrical-------------------------------------------------------------------------13
SECTION 5-Operation------------------------------------------------------------------------16
SECTION 6-Heat Pump Water Heater Maintenance---------------------------------------18
SECTION 7-Trouble Shooting----------------------------------------------------------------19
SECTION 8-Warranty-------------------------------------------------------------------------20
-4-
The GEYSER 6000-3.0™ will remove moisture from the air. It is an effective
dehumidifier, and, depending on run time, may provide all necessary
dehumidification. However, it will only dehumidify while it is running. As more hot
water is used, more dehumidification is provided.
The moisture may occasionally cause frost to form on the evaporator. When the frost
builds up, the GEYSER 6000-3.0 will go into a defrost cycle. This could occur every
two hours of operation in a cold, humid environment. While in a defrost mode period
of 6 minutes, the fan will continue to run and the tank lower heating element will
provide heat. When the defrost period is completed, the GEYSER 6000-3.0™ will
resume heating water.
Temperature Setting: The default setting for the thermostat/temperature setting is
120°F. (49°C.), in accordance with the U.S. Department of Energy Guidelines. Please
note that the GEYSER 6000-3.0™ will heat the water up to 140°F. (60°C.), and this
setting can be changed internally. The lever to adjust the temperature setting is
located inside the electric box within the Geyser. To access it, first disconnect the
power at the fuse or breaker box. Then, remove the rubber mounts on the bottom of
the GEYSER and gently pull the sides away at the bottom and lift the cover off. The
electric box is in the top of the unit, and within the electric box is an electronic
circuit board. At one end of the board is a slide thermostat with temperature
markings. Move the slide to the desired position you want to maintain in the tank,
and replace the cover to the unit.
Check illuminated lights on Geyser unit
Green solid LED-unit is on standby (Geyser is on, but not called to
heat water).
Green flashing LED-unit is on and calling for heat (compressor
working/heat to tank).
Red LED flashes once every two seconds-unit is in defrost mode.
Red LED flashes once every half second-the unit is in over current
mode:. Note: unplug the unit and ensure all wiring is
connected properly. If yes, then call for service.
Red LED flashes 3 times-the thermistor is disconnected/broken
for water temperature detection: If this condition persists, call
for service.
Red LED flashes 4 times-thermistor is disconnected/broken for defrost
temperature detection. If this condition persists, call for
service.
-17-

Advertisement

Table of Contents
loading

Table of Contents