Haier HSU-18CV03(T3) Operation Manual
Haier HSU-18CV03(T3) Operation Manual

Haier HSU-18CV03(T3) Operation Manual

Haier room air conditioner operation manual

Advertisement

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-18CV03(T3)
HSU-24CV03(T3)
Please read this operation manual before using the air conditioner
No.0010556977

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-18CV03(T3)

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-18CV03(T3) HSU-24CV03(T3) Please read this operation manual before using the air conditioner No.0010556977...
  • Page 2 Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 3 Cautions Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
  • Page 4: Safety Instruction

    Installation Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place.
  • Page 5 Cautions When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Connect power supply cord to the outlet completely STRICT ENFORCEMENT Do not use power supply cord in a bundle. PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on.
  • Page 6: Parts And Functions

    Parts and Functions Indoor unit Display board Inlet Air Purifying Filter (inside) Inlet grille Vertical flap (adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) For 24k unit, the power plug is on the outdoor unit Outdoor unit HSU-18CV03(T3) INLET...
  • Page 7 Parts and Functions FRESH STERILIZE 1.CODE Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation. 2.RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
  • Page 8 Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. 2. Press to set correct time. Each press will increase or decrease 1 min.
  • Page 9: Remote Controller

    BRIEF INTRODUCTION TO HEALTH ANION FUCTION The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
  • Page 10: Auto Operation

    Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5.Unit stop Press ON/OFF button, the unit stops.
  • Page 11: Cool Operation

    Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. 5.Unit stop Press ON/OFF button, the unit stops.
  • Page 12: Dry Operation

    4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
  • Page 13: Fan Operation

    Operation Fan Operation Remote controller FRESH STERILIZE 1. Unit start Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO Then Select FAN operation 3.Fan speed selection Press FAN button.
  • Page 14: Heat Operation

    Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 15: Air Flow Direction Adjustment

    Operation Air Flow Direction Adjustment 1.Status display of air sending FRESH STERILIZE 2.Up and down air flow direction For each press of as follows according to different operation modes: COOL/DRY/FAN remote controller: Pos.1 HEAT: remote controller: Pos.5 AUTO: Pos.1 remote controller: The vertical flap will swing according to the above positions 3.Left and right air flow direction For each press of...
  • Page 16: Sleep Operation

    Operation Sleep Operation Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
  • Page 17: Timer On/Off Operation

    Operation Timer On/Off Operation Remote Controller FRESH STERILIZE Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. Set clock correctly before starting TIMER operation.
  • Page 18 Operation Timer On-Off Operation Remote Controller FRESH STERILIZE Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: TIMER ON...
  • Page 19: Health Airflow Operation

    3.In cooling, it is better to select the mode. 4.In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille . 5.Select the appropriate fan direction according to the actual...
  • Page 20: Emergency And Test Operation

    Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
  • Page 21: Maintenance

    Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Close doors and windows during operation If the unit is not to be used for a long time, turn off the power supply main switch. Do not block the air inlet...
  • Page 22: Air Filter Cleaning

    Close the inlet grille. Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
  • Page 23 Maintenance Replancement of Air Purifying Filter 1.Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push 2.Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3.Attach new Air Purifying Filter Put air purifying filter appliances into the right and left filter frames.
  • Page 24: Cleaning The Body

    Maintenance To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 mode and High speed fan mode for 2-3 hours.
  • Page 25: Connecting The Earthing Cable

    Maintenance Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable. Incomplete earthing may cause an electric shock.
  • Page 26: Troubleshooting

    When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable.