The new Phoenix Arctic Max is the first portable air condi-
tioner designed specifically for the Restoration Industry.
The Phoenix Arctic Max boasts one ton (2,000 BTUs) of
cooling capacity operating in 95°F and 60% conditions while
drawing under 2 amps. In a single pass, this provides a
5 degree temperature drop on the 430 CFM evaporator
(cooling) air stream and water removal equivalent to 00
pints per day.
The Phoenix Arctic Max gives the restoration contractor vital
temperature control in the affected area to optimize drying
efficiency or in unaffected areas to safe-guard occupant
comfort. The Phoenix Arctic Max's cooling power also
makes it the ideal accessory to pre-treat air to improve the
The Phoenix Arctic Max
Portable Air Conditioner
•  Ton, 2,000 BTUs of Cooling*
• 00 Pints/Day of Water Removal*
• .7 Amps*
• Adjustable Thermostat
• Easy Set-up and Operation
• Cooling (Evaporator) Airflow 430 CFM
• Exhaust (Condenser) Airflow 430 CFM
• Multiple Ducting Options
• Multiple Filter Options
• 20 ft. Vertical Lift Condensate Pump
• 30 ft. Drain Hose
• 20 ft. Power Cord (grounded)
• Recessed Wheels
• Legendary Stainless Construction
*95ºF/60% RH
Specifications subject to change without notice.
Toll-Free 1-800-533-7533
PO Box 8680 • Madison, WI 53708
Installation, Operation and Service Instructions
Read and Save These Instructions
performance of desiccant or LGR dehumidifiers. When used
in conjunction with the Phoenix Solution LGR performance
amplifier, the Phoenix Arctic Max provides a reliable cooling
air stream to maximize overall performance. The Phoenix
Arctic Max features thermostatically controlled cooling to
insure maintenance of desired conditions and prevent
potential over-cooling.
Set-up and operation is simple using the Phoenix window
accessory kit, and a 5 amp outlet. The Phoenix Arctic Max
also features filter efficiency options up to MERV-, an
internal condensate pump with 30 foot drain hose and 20
foot power cord. The Phoenix Arctic Max promises years of
service and our "proven" performance.
Phoenix Arctic Max
PN 4026850

www.thermastor.com • sales@thermastor.com
Arctic Max
TS-388
Revised 4/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS-388 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Phoenix TS-388

  • Page 1 Arctic Max TS-388 PO Box 8680 • Madison, WI 53708 Owner’s Manual — Phoenix Arctic Max Installation, Operation and Service Instructions Read and Save These Instructions The new Phoenix Arctic Max is the first portable air condi- performance of desiccant or LGR dehumidifiers. When used tioner designed specifically for the Restoration Industry.
  • Page 2: Table Of Contents

    1 Specifications Table of Contents Introduction .............. Part No. 4026850 1. Specifications ............2 Power .7 amps@ 95°F/60% RH 2. Operation .............3 2,000 Btu/Hr, 00 ppd 2. Transporting ...........3 Adjustable 60-00 2.2 Electrical Requirements ........3 Thermostat 2.3 Condensate Removal ........3 Range 2.4 Ducting ............3 Cooling Airflow 430 CFM...
  • Page 3: Operation

    2 Operation 2.1 Transporting Condenser Exhaust Ducted Air Stream The Phoenix Arctic Max must always be upright when transported by vehicle. It may be tipped onto its handle and back for loading and moving by hand. The Phoenix Duct out of Arctic Max features a high-impact plastic skid plate which Conditioned Space protects the unit while navigating obstacles such as curbs,...
  • Page 4: Low Pressure Control

    To adjust the defrost timer: The filter can generally be vacuumed clean several times before needing replacement. Replacement filters can be . Unplug the unit. ordered from the factory or purchased locally if available. 2. Remove the top panel and the front cover (6 screws). 3.
  • Page 5: Troubleshooting

    No dehumidification, blower runs but compressor does not. . Bad connection in compressor circuit. 2. Pump safety switch closed. 3. Defective compressor capacitor. 4. Defective compressor overload. 5. Defective compressor. 6. Defective relay. Blower does not run. Compressor runs briefly but cycles on and off.
  • Page 6: Blower Replacement

    4.3 Blower Replacement The motorized impeller has a PSC motor and internal thermal overload protection. If defective, the complete assembly must be replaced. . Unplug the power cord. 2. Remove the top and cabinet front (6 screws). 3. Disconnect the impeller leads. 4.
  • Page 7: Wiring Diagram

    HOUR BUTTON METER EVAP FAN CAP CONDENSATE PUMP FLOAT SWITCH OVERLOAD COMPRESSOR PUMP SAFETY PURGE SWITCH SWITCH CONNECTOR PART NO. REV. Therma-Stor LLC PO BOX 8680, MADISON, WI 53708 4026843 1-800-533-7533 Figure 8: Wiring diagram Toll-Free 1-800-533-7533 www.thermastor.com • sales@thermastor.com...
  • Page 8: Service Parts

    8 Service Parts Item Description Part No. Filter, Cooling, 2 x 6 x 20 402475 Cord 4025078 Front Panel Retaining Nut, /4-20 6 4023362 Wheel, 8” 4025676 Wheel Hub Cap 402486 Retaining Ring 4025454 Hub Cap Retaining Washer 4025295 Coupling Body, /4 Tube 402490 Foot 4024073...
  • Page 9: Warranty

    Who Is Covered: This warranty extends only to the original end-user of the Phoenix Arctic Max, and may not be assigned or transferred. Year One: Therma-Stor LLC warrants that, for one () year the Phoenix Arctic Max will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the defective part(s), free of any charge.

This manual is also suitable for: