Monitoring MetPak RG Output Data Using
HyperTerminal.
NOTE. This section describes the procedure using Windows HyperTerminal.
Alternatively Gill Wind Software (http://www.gill.co.uk/main/software.html) can be
used a Terminal Emulator (note Tools feature not applicable). Select the required
COM port and click on OK, the required 19200 Baud Rate is already selected (or
use the Baudrate drop down) then continue as from step 7.
Establishing a HyperTerminal Connection
To monitor MetPak RG data using HyperTerminal:
1.
Select an available Com port and connect the MetPak RG unit.
2.
Run Hypertrm.exe (Typically accessed via:-
Start | All Programs | Accessories | Communications | Hyperterminal).
3.
Select New Connection from the File menu.
4.
Enter a name for the connection, for example MetPak RG and, optionally,
select an icon to represent it. Click on the OK button.
5.
In the Connect To dialog box, change Connect Using to COMX (where X is
the number of the selected COM port). Click on the OK button.
6.
In the COMX Properties dialog box, adjust the Port settings to match the
MetPak RG unit's settings. The default settings are :
Bits per second
Data bits
Parity
Stop bits
Flow Control
7.
Click on the OK button.
Message Reporting
MetPak RG has two reporting modes:
Continuous mode
In continuous mode (the default) MetPak RG reports continuously. So, if you have
set up the connection correctly, you should now see data strings scrolling across
the HyperTerminal window. For example:
 Q,262,000.04,1
024.3,051.6,+023.5,+012.9,0000.000,+04.8,00, 62
Polled mode
If the unit has been set to polled mode type ?Q (where Q is the unit node letter) to
prompt one line of the data string. Note, allow 9.5 seconds after switching on the
unit before sending a poll command.
When polled, allow 570 milli-seconds for the unit to respond with a line of data. If
the MetPak RG detects a pressure/temperature/humidity sensor fault then allow 4
seconds for an error data output.
Enter SETUP MODE to check Ser. Number and Firmware Version
To enter the unit's setup mode:
If the unit is in continuous reporting mode, type *.
If the unit is in polled mode, type *Q (where Q is the unit node letter).

MetPak RG User Manual

©
Gill Instruments Ltd
19200
8
None
1
None