Service And Adjustment; Tank (Sediment) Cleaning; Venting System Inspection; Burner Inspection - Kenmore 153.331544 Owner's Manual

Gas water heater
Hide thumbs Also See for 153.331544:
Table of Contents

Advertisement

Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying
amount of noise, and if left in the tank will cause permanent
tank failure. In some water areas, you may not be able to drain
all sediment deposits by simply draining the tank. In these
cases Mag-Erad (part no. 23600) can be used to help remove
the sediment deposits. This may be ordered from the Sears
Service Center. For ordering, refer to the Parts Order List
section.
Vent System Inspection
• Flue gases may escape if vent pipe
is not connected.
• Be alert for obstructed, sooted or
deteriorated vent system to avoid
serious injury or death.
• Do not store corrosive chemicals
in vicinity of water heater.
• Chemical corrosion of flue and vent
system can cause serious injury or
death
At least once a year a visual inspection should be made of the
venting system. You should look for:
• Obstructions which could cause improper venting. The
combustion and ventilation air flow must not be obstructed.
• Damage or deterioration which could cause improper
venting or leakage of combustion products.
• Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape
of dangerous flue gasses which could cause deadly
asphyxiation.
Obstructions and deteriorated vent systems may present
serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air
conditioner refrigerants, swimming pool chemicals, calcium
and sodium chloride, waxes, bleach and process chemicals
are typical compounds which are potentially corrosive.
If when inspecting the vent system you find sooting or
deterioration, something is wrong. Call the local gas supplier
to correct the problem and clean or replace the flue and venting
before resuming operation of the water heater.

SERVICE AND ADJUSTMENT

20

Burner Inspection

Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a
flooded water heater will create dangerous conditions
can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. Contact a Sears Service Center to replace a flooded
water heater. Do not attempt to
replaced!
At least once a year a visual inspection should be made of the
main burner and pilot burner. See Figure 23.
You should check for sooting. Soot is not normal and will
impair proper combustion.
Soot build-up indicates a problem that requires correction
before further use. Turn "OFF" gas to water heater and
leave off until repairs are made, because failure to correct the
cause of the sooting can result in a fire causing death, serious
injury, or property damage.
FIGURE 23.

Burner Cleaning

In the event your burner needs cleaning, following these
instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise (
depressing slightly.
NOTE: The knob cannot be turned from "PILOT" to "OFF"
unless knob is depressed slightly. DO NOT FORCE.
The burner needs to be removed for cleaning. Call the Sears
Service Center to remove and clean the burner and correct the
problem that required the burner to be cleaned.
which
repair the unit! It must be
) to the "OFF" position,