Weekly Maintenance Procedures - Kodak 5500 Maintenance Procedures

Maintenance and feeder adjustment procedures
Hide thumbs Also See for 5500:

Advertisement

Weekly maintenance
procedures
4
10. Swing the vertical transport plate closed and rotate the release
handle 180 counterclockwise (so the red arrow aligns with the
red rectangle) to latch the plate.
11. Close side access door.
12. Close the upper access door.
NOTE: Imaging guides are not interchangeable. They can only be
inserted one way.
In addition to the daily cleaning procedures previously mentioned,
these items require weekly attention.
Vacuuming inside the scanner
Vacuuming the horizontal transport area
Cleaning the exterior of the cabinet
Vacuuming inside the scanner
Clean weekly or more frequently if necessary to remove any dust
or debris.
Vacuuming the horizontal transport area
1. Turn the power off and lift open the lower access door.
2. Lift the release bar and raise the front scan module.
NOTE: If the Patch Reader Accessory is installed, the Patch
Reader must be removed from the mounting plate in
order to lift up the horizontal transport plate.
3. Lift up and latch the horizontal transport plate into its open
position.
4. Remove the lower belt module. Clean it and set it aside.
5. Vacuum the area underneath the belt module.
6. Replace the belt module.
7. Release and lower the horizontal transport plate back into its
original position.
8. Lower the release bar and latch the front scan module into its
original position.
9. Close the lower access door.
10. Open the upper access door.
11. Open the right side access door.
12. Release and open the vertical transport plate by rotating the
release handle 180 clockwise.
A-61603 September 1998