CS1782 / CS1784 User Manual FCC Information Federal Communication Commission Interference Statement: This equipment has been tested and found to comply with the limits for a Class B digital service, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
86-10-5255-0110 Japan 81-3-5615-5811 Korea 82-2-467-6789 North America 1-888-999-ATEN ext 4988 United Kingdom 44-8-4481-58923 User Notice All information, documentation, and specifications contained in this manual are subject to change without prior notification by the manufacturer. The manufacturer makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose.
CS1782 / CS1784 User Manual About this Manual This User Manual is provided to help you get the most from your CS1782 CS1784 . It covers all aspects of installation, configuration and operation. An overview of the information found in the manual is provided below. Chapter 1, Introduction, introduces you to the CS1782 / CS1784 system.
For information about all ATEN products and how they can help you connect without limits, visit ATEN on the Web or contact an ATEN Authorized Reseller. Visit ATEN on the Web for a list of locations and telephone numbers: International http://www.aten.com...
Digital Visual Interface (DVI) monitor. In addition, the CS1782 / CS1784 comes with ATEN’s new Video DynaSync technology, which eliminates boot-up display problems and optimizes resolution, and power on detection, which means if one computer is...
Page 10
CS1782 / CS1784 User Manual two sets of speakers on a one-computer-at-a-time basis. As with the USB peripherals, the audio focus can be independent of the KVM focus. Setup is fast and easy; simply plug cables into their appropriate ports. There is no software to configure, no installation routines, and no incompatibility problems.
2560 x 1600 @ 60Hz (Dual Link) Supports widescreen resolutions Video DynaSync – Exclusive ATEN technology eliminates boot-up display problems and optimizes resolution when switching between ports Power on detection – if one of the computers is powered off, the switch...
Page 12
CS1782 / CS1784 User Manual Multilingual keyboard mapping – supports English, Japanese, and French keyboards Auto Scan Mode for monitoring all computers Firmware upgradable Note: 1. PC keyboard combinations emulate Mac/Sun keyboards 2. Mac/Sun keyboard work only with their own computers...
Chapter 1. Introduction Hardware Requirements Console A DVI compatible monitor capable of the highest possible resolution A USB mouse A USB keyboard Microphone and speakers (optional) Computers The following equipment must be available on each computer: A DVI port Note: The video quality of the display is affected by the performance of the graphics card.
CS1782 / CS1784 User Manual Operating Systems Supported operating systems are shown in the table, below: Version Windows 2000 / XP / 2003 / 2008 / Vista / 7 Linux RedHat 9.0 and higher SuSE 10 / 11.1 and higher Debian 3.1 / 4.0 Ubuntu...
Chapter 1. Introduction Components CS1782 Front View CS1784 Front View...
Page 16
CS1782 / CS1784 User Manual Component Description Port For manual port selection (see Overview, page 15, also): Selection Press a port selection pushbutton for less than two seconds to Pushbuttons bring the KVM, USB hub, and audio focus to the computer attached to its corresponding port.
Page 18
CS1782 / CS1784 User Manual Component Description Console The cables from your DVI monitor, USB keyboard, USB Port Section mouse, speakers, and microphone plug in here. Each connector is marked with an appropriate icon to indicate itself. KVM Port The cables that link the switch to your computers plug in Section here.
Chapter 2 Hardware Setup 1. Important safety information regarding the placement of this device is provided on page 39. Please review it before proceeding. 2. Make sure that power to all the devices you will be installing has been turned off. You must unplug the power cords of any computers that have the Keyboard Power On function.
Page 20
CS1782 / CS1784 User Manual Note: Verify that all the plugs are in the same KVM Port sockets (all in Port 1, all in Port 2, etc.). Each socket is marked with an appropriate icon. 6. At the other end of the cable, plug the USB, video, microphone, and speaker cables into their respective ports on the computer.
Chapter 3 Basic Operation Overview There are three convenient methods to access the computers: Manual – which involves pressing the port selection pushbuttons located on the unit’s front panel; Mouse – which involves clicking the scroll wheel of the mouse; and Hotkey –...
CS1782 / CS1784 User Manual Mouse Port Switching The CS1782 / CS1784 supports the very latest in mouse port-switching – simply double-click the scroll wheel of your USB mouse to cycle through the ports. Note: 1. This featured is only supported by USB 3-key scroll wheel mice. 2.
Chapter 3. Basic Operation Port ID Numbering Each KVM port section on the CS1782 / CS1784 switch is assigned a port number. (1 or 2 for the CS1782 ; 1 to 4 for the CS1784 ). The port numbers are marked on the rear panel of the switch (see page 9 for details). The Port ID of a computer is derived from the KVM port number it is connected to.
Page 26
CS1782 / CS1784 User Manual This Page Intentionally Left Blank...
Chapter 4 Hotkey Operation The CS1782 / CS1784 provides an extensive, easy-to-use, hotkey function that makes it convenient to control and configure your KVM installation from the keyboard. Hotkeys provide independent switching of the KVM, USB hub, and audio focus. Therefore, you can give one computer the KVM focus, another the USB hub focus, while a third has the audio focus.
CS1782A / CS1784A User Manual Going Directly to a Port Hotkey Action [Scroll Lock] [Scroll Lock] Brings the KVM, USB hub, and audio focus to the [n] [Enter] computer attached to the port corresponding to the specified Port ID. Note: The KVM, USB hub, and audio focus all go to this port even if they were on different ports to begin with.
Lock] [A] [n] [Enter] Note: The n stands for the number of seconds that the CS1782A / CS1784A should dwell on a port before moving on to the next. Replace the n with a number between 1 and 99 when entering this hotkey combination Note: 1.
CS1782A / CS1784A User Manual Hotkey Setting Mode Hotkey Setting Mode is used to set up your CS1782 / CS1784 switch configuration. All operations begin with invoking Hotkey Setting Mode (HSM). Invoking HSM To invoke HSM do the following: 1. Press and hold down [Num Lock].
Chapter 4. Hotkey Operation Alternate HSM Invocation Keys An alternate set of HSM invocation keys is provided in case the default set conflicts with programs running on the computers. To switch to the alternate HSM invocation set, do the following: 1.
CS1782A / CS1784A User Manual Keyboard Operating Platform The CS1782 / CS1784 ’s default port configuration is for a PC compatible keyboard operating platform. If your console uses a PC compatible keyboard and you have a Mac attached to a port, for example, you can change the port’s keyboard operating platform configuration so that the PC compatible keyboard emulates the Mac keyboard.
Chapter 4. Hotkey Operation USB Reset If the USB loses focus and needs to be reset, do the following: 1. Invoke HSM (see page 22). 2. Press and release [F5]. Keyboard Language To change the keyboard language, do the following: 1.
2. Press [R] [Enter]. See Hotkey Default Settings, page 46 Video DynaSync Video DynaSync is ATEN’s exclusive technology that eliminates boot-up display problems and optimizes resolution when switching between ports. To invoke Video DynaSync, do the following: 1. Invoke HSM (see page 22) 2.
Chapter 4. Hotkey Operation Mouse Emulation Control The default setting is enabled. To disable, do the following: 1. Invoke HSM (see page 22 2. Press [M]. This procedure is a toggle. Repeat to enable. Mouse Port-switching The Mouse Port-switching function can be enabled or disabled. The default setting is disabled.
CS1782A / CS1784A User Manual Power on Detection With Power on Detection if the focus computer is powered off, the switch will automatically switch to the next powered-on computer. Power on Detection can be enabled or disabled. The default setting is enabled. To disable Power on Detection, do the following: 1.
Invokes Firmware Upgrade Mode. See The Firmware Upgrade Utility, [d] [e] [Enter] page 33, for full details. Invokes Video DynaSync, ATEN’s exclusive technology that eliminates boot-up display problems and optimizes resolution when switching between ports. Enables/Disables the Power on Detection feature. See Power on Detection, page 28 for details.
Page 38
CS1782A / CS1784A User Manual Function [F1] Sets the SPC mode so that it can work under special operating systems as a standard (104 key) keyboard/mouse.
Chapter 5 Keyboard Emulation Mac Keyboard The PC compatible (101/104 key) keyboard can emulate the functions of the Mac keyboard. The emulation mappings are listed in the table below. PC Keyboard Mac Keyboard [Shift] Shift [Ctrl] Ctrl [Ctrl] [1] [Ctrl] [2] [Ctrl] [3] [Ctrl] [4] [Alt]...
CS1782 / CS1784 User Manual Sun Keyboard The PC compatible (101/104 key) keyboard can emulate the functions of the Sun keyboard when the Control key [Ctrl] is used in conjunction with other keys. The corresponding functions are shown in the table below. PC Keyboard Sun Keyboard [Ctrl] [T]...
Utility comes as part of a Firmware Upgrade Package that is specific for each device. Check the web site regularly to find the latest packages and information relating to them: http://www.aten.com Before you Begin 1. From a computer that is not part of your KVM installation go to our...
Page 42
CS1782 / CS1784 User Manual 5. Invoke Firmware Upgrade Mode (see Firmware Upgrade Mode, page 26). The front panel orange LEDs flash to indicate that Firmware Upgrade Mode is in effect. USB DVI KVM Cable Set...
Chapter 6. The Firmware Upgrade Utility Starting the Upgrade 1. Run the downloaded Firmware Upgrade Package file – either by double clicking the file icon, or using a command line to enter the full path. The Firmware Upgrade Utility Welcome screen appears: 2.
Page 44
CS1782 / CS1784 User Manual 4. As you select a device in the list, its description appears in the Device Description panel.After you have made your device selection(s), Click Next to perform the upgrade. If you enabled Check Firmware Version, the Utility compares the device’s firmware level with that of the upgrade files.
Chapter 6. The Firmware Upgrade Utility Upgrade Succeeded After the upgrade has completed, a screen appears to inform you that the procedure was successful: Click Finish to close the Firmware Upgrade Utility. After a successful completion, the CS1782 / CS1784 exits Firmware Upgrade Mode, and resets itself.
Page 46
CS1782 / CS1784 User Manual This Page Intentionally Left Blank...
Appendix Safety Instructions This product is for indoor use only. Read all of these instructions. Save them for future reference. Follow all warnings and instructions marked on the device. Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.
Page 48
CS1782 / CS1784 User Manual If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
Appendix Technical Support International For online technical support – including troubleshooting, documentation, and software updates: http://eservice.aten.com For telephone support, see Telephone Support, page iii. North America Email Support support@aten-usa.com Online Troubleshooting http://www.aten-usa.com/support Technical Documentation Support Software Updates Telephone Support 1-888-999-ATEN ext 4988 When you contact us, please have the following information ready beforehand: Product model number, serial number, and date of purchase.
CS1782 / CS1784 User Manual Specifications Function CS1782A Computer Connections Port Selection Front Panel Pushbuttons, Hotkeys, Mouse Connectors Keyboard 1 x USB Type A Female (Black; rear panel) Console Ports Video 1 x DVI-I Female (white) Mouse 1 x USB Type A Female (Black; rear panel)
Page 51
Appendix Function CS1784A Computer Connections Port Selection Front Panel Pushbuttons, Hotkeys, Mouse Connectors Keyboard 1 x USB Type A Female (Black; rear panel) Console Port Video 1 x DVI-I Female (white) Mouse 1 x USB Type A Female (Black; rear panel) Audio Speaker 2 x Mini Stereo Jack Female (Green;...
CS1782 / CS1784 User Manual Troubleshooting Operation problems can be due to a variety of causes. The first step in solving them is to make sure that all cables are securely attached and seated completely in their sockets. In addition, updating the product’s firmware may solve problems that have been discovered and resolved since the prior version was released.
Page 53
Appendix (Continued from previous page.) Symptom Possible Cause Action When switching to Graphics card is Adjust the graphics card settings to digital an HDMI DVI-I (Digital and only. computer, there is Analog). Replace graphics card with DVI-D or HDMI no display on the graphics card.