Is4 Spa-Side Remote Gunite Installation - Pentair iS4 Installation And User Manual

Spa-side remote control for use with pentair control systems
Table of Contents

Advertisement

NOTE: If the Automation Load Center or Power Center to which the spa-side
remote is connected is not located above the spa water level, a junction box
should be provided (above water level).

iS4 SPA-SIDE REMOTE GUNITE INSTALLATION

1. When plumbing the spa, install a 3 in. to 6 in. length of 1 in. Sch 40
PVC pipe (perpendicular to the spa wall) to provide a receptacle for
the spa-side remote. Plumb the pipes level as possible. The "eyeball"
design built into the remote compensate for a discrepancy of up to
15°. See Figure 1.
2. The pipe should protrude beyond the finished surface of the spa, as
it will be cut back after surface-finishing is completed. Outside the
spa, the conduit size may be reduced down to ½ in. or ¾ in., and run
to the Control Power/Load Center.
3. Use sweep elbows for turns.
NOTE: For new gunite spa installations, the iS4 Mounting Adapter
has no purpose and can be discarded.
.
Figure 1
iS4 Spa-Side Remote
NOTE: DO NOT affix unit with epoxy to enable future
upgrades.
1 in. PVC conduit
~15°
iS4 Spa Side Remote Installation and User's Guide