Service Diagnosis; No Ice Production - Hoshizaki F-800MAH(-C) Service Manual

Modular flaker
Hide thumbs Also See for F-800MAH(-C):
Table of Contents

Advertisement

V. SERVICE DIAGNOSIS

1. NO ICE PRODUCTION

PROBLEM
[1] The icemaker will
not start.
[2] Water flow does not
stop, and the
icemaker will not
start
[3] Water has been
supplied, but the
icemaker will not
start.
POSSIBLE CAUSE
a)
Power Supply
b)
Power Switch
(Control Box)
c)
Fuse (Control Box)
d)
Circuit Protect Relay
e)
Flush Timer
f)
Flush Switch
g)
Transformer
h)
Control Water Valve
i)
Shut-off Valve
j)
Plug and Receptacle
(Control Box)
a)
Water Control Relay
b)
Float Switch
c)
Flush Water Valve
d)
Hoses
a)
Water Control Relay
b)
Bin Control
c)
Gear Motor Relay
d)
Control Timer
(Printed Circuit
Board)
e)
Gear Motor Protect
Relay
1.
OFF position.
2.
Loose connection.
3.
Bad contacts.
4.
Blown fuse.
1.
Off position.
2.
Bad contacts.
1.
Blown out.
1.
Miswiring.
1.
Flushing out.
2.
Bad contacts.
1.
FLUSH position.
2.
Bad contacts.
1.
Coil winding opened.
1.
Coil winding opened.
1.
Closed.
2.
Water failure.
1.
Disconnected.
2.
Terminal out of Plug
or Receptacle.
1.
Contact fused.
2.
Coil winding opened.
1.
Bad contacts.
2.
Float does not move
freely.
1.
Valve seat clogged
and water leaking.
1.
Disconnected.
1.
Bad contacts.
1.
Bad contacts.
2.
Activator does not
move freely.
1.
Coil winding opened.
2.
bad contacts.
1.
Broken.
1.
Coil winding opened.
2.
Bad contacts.
35
REMEDY
1.
Move to ON position.
2.
Tighten.
3.
Check for contintinuity
and replace.
4.
Replace.
1.
Move to ON position.
2.
Check for continuity
and replace.
1.
Check for short circuit
and replace.
1.
Check power supply
voltage and wire
properly.
1.
Wait for 15 minutes.
2.
Check for continuity
and replace.
1.
Move to ICE position.
2.
Check for continuity
and replace.
1.
Replace.
1.
Replace.
1.
Open.
2.
Wait till water is
supplied.
1.
Connect.
2.
Insert Terminal back in
position
1.
Replace.
2.
Replace.
1.
Check for continuity
and replace.
2.
Clean or replace.
1.
Clean or replace
1.
Connect.
1.
Check for continuity
and replace.
1.
Check for continuity
and replace.
2.
Clean Axle and its
corresponding holes
or replace Bin Control.
1.
Replace.
2.
Check for continuity
and replace.
1.
Replace.
1.
Replace.
2.
Check for continuity
and replace.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-800mwh-cF-800mahF-800mwh

Table of Contents