Aircel VF Series - Models 10 - 1200
Refrigerant Material Safety Data Sheet: R-404a Models 1000 to 1200, continued
SAFETY DATA SHEET
and 453/2010
DuPont
SUVA
Version 4.0
Revision Date 21.11.2012
Further information
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
Personal precautions
6.2. Environmental precautions
Environmental precautions
6.3. Methods and materials for containment and cleaning up
Methods for cleaning up
6.4. Reference to other sections
For disposal instructions see section 13.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Advice on safe handling
Advice on protection
against fire and explosion
7.2. Conditions for safe storage, including any incompatibilities
Requirements for storage
areas and containers
Advice on common storage
Storage temperature
34
according to Regulation (EC) No 1907/2006
®
404A refrigerant
Ref. 130000000494
fire.
: Cool containers / tanks with water spray.
: Evacuate personnel to safe areas. Ventilate area, especially low or enclosed
places where heavy vapours might collect. Refer to protective measures listed
in sections 7 and 8.
: Should not be released into the environment.
In accordance with local and national regulations.
: Evaporates.
:
Avoid breathing vapours or mist. Avoid contact with skin, eyes and clothing.
Provide sufficient air exchange and/or exhaust in work rooms. For personal
protection see section 8.
Vapours are heavier than air and may spread along floors.
:
The product is not flammable in air under ambient conditions of temperature
and pressure. When pressurised with air or oxygen, the mixture may become
flammable. Certain mixtures of HCFCs or HFCs with chlorine may become
flammable or reactive under certain conditions.
:
Do not drag, slide or roll cylinders. Never attempt to lift cylinder by its cap. Use
a check valve or trap in the discharge line to prevent hazardous back flow into
the cylinder. Keep at temperature not exceeding 52° C. Keep containers tightly
closed in a dry, cool and well-ventilated place. Protect from contamination.
Protect cylinders from damage. Keep away from direct sunlight. Store only in
approved containers.
:
No materials to be especially mentioned. For further information see Section 10
of the safety data sheet.
:
< 52 ° C