Summary of Contents for AA Portable Power Corp Universal Smart Charger

  • Page 1 User Manual of Universal Smart Charger (18A, 1500W) for SLA , LFP, Li-Ion Battery Packs from 54V-75V-- CE / UL listed AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19 St, Unit A, Richmond, CA, 94804 Tel: 510-525-2328 Fax: 510-439-2808 Email: Sales@batteryspace.com...
  • Page 2 Warning Must select AC input voltage correctly before plug to • Wall AC outlet Must connect to battery with correct polarity • Must use with battery pack capacity >= 18Ah • Must use with SLA (46V-60V, 23-30Cells), Li- • Ion/LiMnNi (48.1V-62.9V, 13-17Cell), LifePO4 (51.2V- 67.2V, 16-21Cells) Battery Must select charging voltage correctly based on •...
  • Page 3 Features: • High Quality Intelligent smart charger (Model 54-75V/18) designed for SLA (46V-60V, 23- 30Cells), Li-Ion/LiMnNi (48.1V-62.9V, 13-17Cells), LifePO4 (51.2V-67.2V, 16-21Cells) Battery pack Adjustable Charging voltage from 54-75VDC Must select charging voltage correctly based on battery used below Li-Ion / LiMnNi = 4.2V / cell Ex.
  • Page 4: Charging Cycle

    • High Efficiency: 85-95% • MTBF (Mean Time between Failure): 50,000 POH (Power on Hour) = 10 years of everyday operation of 8 hours • UL / CE listed Charging cycle: Stage 1: Constant Current Mode (CC): The charger changes to constant current 18A+/-0.5A. When the battery voltage reaches up to 54-75VDC (Based on voltage selection), the charging stage changes from CC (Constant Current) to CV (Constant Voltage) mode.
  • Page 5 Note - MUST Select AC INPUT Voltage Correctly Before plug to Wall AC outlet. For USA customer, MUST SELECT to “115VAC Input Switch Position” - Must Set charging voltage correctly before connect to battery. - Don’t reset charging voltage while charging. - Wrong charging voltage setting may explode battery.
  • Page 6 Connector Detail Charging Terminal: SB50A Anderson connector SB50A Excluded 1 pcs Polarity assignment & wire soldering Anderson connector for DIY use excluded SB50A Anderson connector Note: -Wrong polarity will damage the charger, and Batteryspace are not responsible for the damage or losses caused by misusing...