HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that
required. But heat requirements often vary. For
example, it usually takes a lot more heat to get things
warm than it does to keep them that way. Likewise,
outside air temperature ususally changes during the day
so you may need more heat at night than you do in the
daytime. An approximation of the heat required can be
found by using the chart below.
BTU'S PER HOUR REQUIRED
Cubic feet
Temperature Rise Required (
of space to
be heated
20
o
5,000
14,000
7,000
19,000
10,000
27,000
15,000
40,000
20,000
54,000
30.000
80,000
50,000
133,000
WARNING: When using a thermostat controled heater,
its exit area should be protected from personnel and
warnings posted of sudden startup.
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V
Amps.
25
5-6
18
6-8
18
8-12
18
10-12
16
12-14
16
Enerco Group, Inc. | Force-Air Propane Construction Heater
o
F)*
30
o
40
o
50
o
20,000
27,999
34,000
28,000
38,000
47,000
40,000
54,000
67,000
60,000
80,000
100,000
80,000
107,000
133,000
120,000
160,000
200,000
200,000
266,000
333,000
Cord Length in Feet
50
100
150
16
14
12
16
12
10
14
12
10
14
10
8
12
10
8
Model #170FAVT

WIRING DIAGRAM

COLOR CODE
B BLACK
R RED
W WHITE
L BLUE
G GREEN
O ORANGE
If any original wiring as supplied by the heater must be
replaced, it must be replaced with type AWG 105° C
wire or its equivalent except as indicated
(*type SF2-200, **SGI 250° C).
170FAVT - WIRING CHART
COLOR
LENGTH
White
7"
Black
6"
Red-(Hi-Temp)
16 1/2"
Red-(Hi-Temp)
16 1/2"
Orange
11"
Green
7"
Red
7"
White
6"
Black
6"
6
Operating Instructions and Owner's Manual
LEGEND
TERMINAL BOARD
Y TERMINAL
MALE CONN
FEMALE CONN
FROM
TO
Valve
Terminal Block
On/Off Switch
Terminal Block
High Limit Switch
Valve
High Limit Switch
Terminal Block
Flame Control
Spark Plug

(Ignition)

Flame Control
Ground
(Harness)
Flame Control
Terminal Block
(Harness)
Flame Control
Terminal Block
(Harness)
Flame Control
Terminal Block
(Harness)
70176 Rev. A 5/05

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Buddy-pro ts170favtHeatstar hs170favt170favt

Table of Contents