Therma-Stor Ultra Aire DEH 3000 Installer's And Owner's Manual

Dehumidifier & ventilation system controller

Advertisement

Quick Links

INSTALLER'S & OWNER'S MANUAL
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
DEH 3000
DEH 3000
Part No. 4028539
Dehumidifier & Ventilation System Controller
4201 Lien Rd Madison, WI 53704
TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
© 2008 Therma-Stor LLC • Manual P/N TS-499e 12/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra Aire DEH 3000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Therma-Stor Ultra Aire DEH 3000

  • Page 1 HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com • • • © 2008 Therma-Stor LLC • Manual P/N TS-499e 12/12...
  • Page 2: Table Of Contents

    Table of Contents 2.1 Install Instructions 1. Contents & Specifications ..........2 1. Separate the front panel from the back panel by depressing 2. Installation ..............2 the middle sections of the top and bottom of the front 2.1 Install Instructions ............2 panel.
  • Page 3: Wiring

    2.2 Wiring The White wire controls the optional motorized damper that can be installed into a fresh air duct. This damper WARNING! provides the ability to control fresh air ventilation using DO NOT ALLOW THE YELLOW the ventilation timer function of the DEH 3000 and the WIRE FROM THE ULTRA-AIRE DEHUMIDIFIER TO CONTACT terminal labeled “DMP”...
  • Page 4: Dehumidifier, Activate/De-Activate With A/C Unit

    Unit Green Yellow 2. Run the Yellow wire from the A/C unit to the COM terminal A voltmeter is required for the next steps to ensure the correct on the DEH 3000. wiring from the A/C transformer is used to set up the Lock-in dehumidifier function.
  • Page 5: Testing

    2.5 Testing d. Release the “VENT” button, then press it again to switch vent mode to “OPEN”. Verify the wiring connections. e. Confirm that the Ultra-Aire fan is ON. Ventilation damper is WARNING! ONLY CONNECT THE WHITE WIRE OPEN. Ultra-Aire compressor must be OFF. TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN f.
  • Page 6: Display

    FOR INSTALLER & HOMEOWNER: seconds, the control will remember any changes made and return to the normal display screen, allowing you to proceed to 3. Operation the next step. On the display screen, a solid “O” in front of any of the 3 3.3 Personal Settings reference list functions (SETPOINT, VENT, FAN) indicates the function is Please record your settings here.
  • Page 7: Fan Setting & Operation

    5. Press the “CLOCK” button again and the day display will 3.7 Fan Setting and Operation flash. Use the “RH” buttons to change the value. Use the “FAN” button to change the fan operation. There are 2 choices for fan operation: “ON” or “AUTO”. The factory preset 6.
  • Page 8: Damper Operation And Ventilation, Manual (Hold) Mode

    3.8 Damper Operation and Ventilation, Manual (Hold) Mode The “VENT” setting controls the ventilation function of the system. It has no control over the dehumidification function. In order to provide ventilation, the motorized damper must be open and the fan must be running. The controller takes care of these two functions automatically so that whenever the damper is open, the fan is running.
  • Page 9: Temperature Cutout Programming

    7-day version or the weekday/weekend split version), use the down “RH” button to highlight the EXIT option and then press “PROGRAM ENTER” to select it. Running the Ventilation Program Press and hold the “PROGRAM ENTER” button until the “PROGRAM” screen appears. Use the down “RH”...
  • Page 10: Warranty

    Controller OR PART THEREOF BE LIABLE UNDER service from an authorized Servicer, he should call ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR Therma-Stor LLC at the above number and ask for the CONSEQUENTIAL DAMAGES INCLUDING WITHOUT Therma-Stor LLC Service Department, which will then LIMITATION WATER DAMAGE (THE END-USER SHOULD arrange for covered warranty service.
  • Page 11 Phone: 608-222-5301 • Fax: 608-222-1447 electronic or mechanical, for any purpose, without the express written permission www.thermastor.com • sales@thermastor.com of Therma-Stor LLC. © 2007 Therma-Stor LLC. All rights reserved. DEH 3000 Dehumidifier & Ventilation System Controller Installation, Operation & Service Manual...