Table of Contents 2.1 Install Instructions 1. Contents & Specifications ..........2 1. Separate the front panel from the back panel by depressing 2. Installation ..............2 the middle sections of the top and bottom of the front 2.1 Install Instructions ............2 panel.
2.2 Wiring The White wire controls the optional motorized damper that can be installed into a fresh air duct. This damper WARNING! provides the ability to control fresh air ventilation using DO NOT ALLOW THE YELLOW the ventilation timer function of the DEH 3000 and the WIRE FROM THE ULTRA-AIRE DEHUMIDIFIER TO CONTACT terminal labeled “DMP”...
Unit Green Yellow 2. Run the Yellow wire from the A/C unit to the COM terminal A voltmeter is required for the next steps to ensure the correct on the DEH 3000. wiring from the A/C transformer is used to set up the Lock-in dehumidifier function.
2.5 Testing d. Release the “VENT” button, then press it again to switch vent mode to “OPEN”. Verify the wiring connections. e. Confirm that the Ultra-Aire fan is ON. Ventilation damper is WARNING! ONLY CONNECT THE WHITE WIRE OPEN. Ultra-Aire compressor must be OFF. TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN f.
FOR INSTALLER & HOMEOWNER: seconds, the control will remember any changes made and return to the normal display screen, allowing you to proceed to 3. Operation the next step. On the display screen, a solid “O” in front of any of the 3 3.3 Personal Settings reference list functions (SETPOINT, VENT, FAN) indicates the function is Please record your settings here.
5. Press the “CLOCK” button again and the day display will 3.7 Fan Setting and Operation flash. Use the “RH” buttons to change the value. Use the “FAN” button to change the fan operation. There are 2 choices for fan operation: “ON” or “AUTO”. The factory preset 6.
3.8 Damper Operation and Ventilation, Manual (Hold) Mode The “VENT” setting controls the ventilation function of the system. It has no control over the dehumidification function. In order to provide ventilation, the motorized damper must be open and the fan must be running. The controller takes care of these two functions automatically so that whenever the damper is open, the fan is running.
7-day version or the weekday/weekend split version), use the down “RH” button to highlight the EXIT option and then press “PROGRAM ENTER” to select it. Running the Ventilation Program Press and hold the “PROGRAM ENTER” button until the “PROGRAM” screen appears. Use the down “RH”...
Controller OR PART THEREOF BE LIABLE UNDER service from an authorized Servicer, he should call ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR Therma-Stor LLC at the above number and ask for the CONSEQUENTIAL DAMAGES INCLUDING WITHOUT Therma-Stor LLC Service Department, which will then LIMITATION WATER DAMAGE (THE END-USER SHOULD arrange for covered warranty service.