INSTALLER'S & OWNER'S MANUAL
DEH 3000R
HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER
DEH 3000R
Part No. 4028407
Dehumidifier & Ventilation System Controller
P.O. Box 8680 Madison, WI 53708
TOLL-FREE 1-800-533-7533
www.thermastor.com
sales@thermastor.com
© 2008 Therma-Stor LLC • Manual P/N TS-506b

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultra-Aire DEH 3000R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Therma-Stor Ultra-Aire DEH 3000R

  • Page 1 INSTALLER’S & OWNER’S MANUAL DEH 3000R HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE 1-800-533-7533 www.thermastor.com sales@thermastor.com • • • © 2008 Therma-Stor LLC • Manual P/N TS-506b...
  • Page 2: Table Of Contents

    Table of Contents 1. Contents & Specifications ... 2 2. Installation ... 2 2.1 Install Instructions ... 2 2.2 Wiring... 3 2.3 Auxiliary Relay, A/C Lockout or Run Central Fan ... 3 2.4 Dehumidifier, Activate/De-Activate with A/C Unit ... 4 2.5 Testing ...
  • Page 3: Wiring

    2.2 Wiring WARNING! DO NOT ALLOW THE YELLOW WIRE FROM THE ULTRA-AIRE DEHUMIDIFIER TO CONTACT THE RED OR WHITE WIRES FROM THE ULTRA-AIRE DEHUMIDIFIER, DAMAGE TO THE 24-VOLT TRANSFORMER WILL RESULT. WARNING! THE REMOTE CONTROL OF THE ULTRA-AIRE DEHUMIDIFIER OPERATES ON A LOW VOLTAGE CIRCUIT (24 VAC) AND MUST NEVER CONTACT OR BE CONNECTED TO A HIGH VOLTAGE CIRCUIT.
  • Page 4: Dehumidifier Lock-Off Or Lock-On

    Green Yellow 2. Run the Yellow wire from the A/C unit to the COM terminal on the DEH 3000R. Green Yellow Energize the A/C central fan during dehumidification To automatically run the A/C FAN when the dehumidifier runs. 1. Attach a second Green wire to the Green fan wire terminal on the thermostat.
  • Page 5: Testing

    2.5 Testing Verify the wiring connections. WARNING! ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN ELECTRIC DAMPER, OTHERWISE TRANSFORMER DAMAGE MAY RESULT. After checking the wiring, this short test will confirm proper hook-up.
  • Page 6: Display

    FOR INSTALLER & HOMEOWNER: 3. Operation On the display screen, a solid “O” in front of any of the 3 functions (SETPOINT, VENT, FAN) indicates the function is operating. A flashing “O” indicates it is in a wait mode and not available at the moment.
  • Page 7: Fan Setting & Operation

    5. Press the “CLOCK” button again and the day display will flash. Use the “RH” buttons to change the value. 6. Don’t touch any buttons for several seconds until the display stops flashing, this will save your settings. If you need to change anything go back to step #1.
  • Page 8: Damper Operation And Ventilation, Manual (Hold) Mode

    3.8 Damper Operation and Ventilation, Manual (Hold) Mode The “VENT” setting controls the ventilation function of the system. It has no control over the dehumidification function. In order to provide ventilation, the motorized damper must be open and the fan must be running. The controller takes care of these two functions automatically so that whenever the damper is open, the fan is running.
  • Page 9: Temperature Cutout Programming

    You can select from: “MON-FRI” “SAT-SUN” for separate weekday and weekend schedules, or “MON-SUN” which gives you equal weekday and weekend schedules. 3. Using the Up/Down “RH” buttons, highlight and then select one of the two choices. The example given shows how to program separate weekday and weekend schedules.
  • Page 10: Deh3000R

    5.0 DEH3000R — Remote sensor option. This section is applicable only to customers who have purchased a remote sensor package. The standard DEH 3000 controller does not offer remote functionality. 5.1 Remote Sensor Usage IMPORTANT! • The use of spray paint on the sensor housing may damage the sensor and is not covered by the product warranty.
  • Page 11: Warranty

    DEH 3000R Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants as follows: (i) the DEH 3000R (“Product”) will be free of material defects in workmanship or materials for a period of three (1) year (“One-Year Warranty”) following the date of initial purchase of such Product by an original customer purchasing from Therma-Stor or an authorized reseller (“Customer”);...
  • Page 12 PO Box 8680 • Madison, WI 53708 Phone: 608-222-5301 • Fax: 608-222-1447 www.thermastor.com • sales@thermastor.com DEH 3000R Dehumidifier & Ventilation System Controller Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Therma-Stor LLC.