Push-Button Alarms; Pull-Cord Alarm; Man-Down & No-Movement Alarm - ASCOM a51 User Manual

Alarm transmitter
Hide thumbs Also See for a51:
Table of Contents

Advertisement

User Manual
Ascom a51 Alarm Transmitter
Configuration of push-button alarms
The following parameters are configurable:
• Alarm type for multiple press
• Alarm type for single press (long press 1 s. by default)
• Time of push-button press for single press
• Number of presses for multiple press alarm
• ALS
5.2

Pull-cord Alarm

An alarm is sent when the pull-cord is pulled off the Alarm Transmitter. Depending on set
parameters, a beep/vibrator/LED signal confirms that the alarm has been sent.
Note: Make sure that the clip of the Pull-cord is safely attached to the clothes. To make a
test, remove the battery of the Alarm Transmitter, pull the Alarm Transmitter and make
sure that the pull-cord releases first.
Configuration of Pull-cord Alarm
• ALS
5.3
Man-down & No-movement Alarm
Man-down alarm: The Alarm Transmitter is tilted more than 55º for a preset time, for
example when falling.
No-movement alarm: Movement is not detected during a pre-set time.
Before the alarm is sent, the Alarm Transmitter enters a warning phase called Man-down/
No-movement Warning (MDW), with a repeated warning tone (default: 7 seconds). The
beep signal always starts with a pair of low volume beeps and then continues with high
volume beeps, and is alternating with the vibrator.
Press the Mute button during this warning phase to prevent the alarm from being sent.
If the Mute button is not pressed an alarm is sent. Depending on set parameters, a beep/
vibrator/LED signal confirms that the alarm has been sent.
Extra Delay
If the parameter "Extra delay" is enabled, the detection of Man-down & No-movement
alarm can be disabled for 10 minutes. When the warning signal sounds, press and hold
the Mute button to delay the next warning signal 10 minutes. One long beep followed by
vibrator indicates that the Extra delay is set.
Configuration of
The following parameters are configurable:
• Time of Man-down detection phase (time of a tilted state)
• Time of No-movement detection phase (time of a non moving state)
• Time of Man-down/No-movement Warning (MDW) phase
• ALS activation
• Extra delay activation
2007-03-15/ Ver. C
Man-down & No-movement Alarm
TD 92351GB