Elektral ThruScan User Manual

Elektral ThruScan User Manual

Multizone walk through metal detectors
Table of Contents

Advertisement

European Branch:
Elektral Businesspool GmbH
Hatzper Bogen 27,
D-45133 Essen
GERMANY
Phones :+49(0)201 814 10948
Fax
:+49(0)201 364 4342
e-mail :elektral@elektral.com
www.ThruScanmetaldetectors.com
WTMD
U
s
U
s
MAIN CONTACT-FACTORY:
Elektral Elektromekanik A.S.
Ataturk Industrial Zone
M.K. Ataturk Blv. 23 Cigli
35620 Izmir -TURKEY
Phones : +90(0)232 376 7300
Fax
e-mail
www.elektral.com.tr
e
r
'
s
M
a
n
e
r
'
s
M
a
n
Release: 05.12
: +90(0)232 376 7030
: elektral@elektral.com.tr
u
a
l
u
a
l

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ThruScan and is the answer not in the manual?

Questions and answers

Summary of Contents for Elektral ThruScan

  • Page 1 WTMD ’ ’ Release: 05.12 European Branch: MAIN CONTACT-FACTORY: Elektral Businesspool GmbH Elektral Elektromekanik A.S. Hatzper Bogen 27, Ataturk Industrial Zone D-45133 Essen M.K. Ataturk Blv. 23 Cigli GERMANY 35620 Izmir -TURKEY Phones :+49(0)201 814 10948 Phones : +90(0)232 376 7300...
  • Page 2: Table Of Contents

    Contents Page PRAFACE......................4 Contents ......................5 Before Use ......................6 1. GENERAL DESCRIPTION .................. 8 ThruScan s3 Walk Through Metal Detector..........9 ThruScan s9 Walk Thru Metal Detector…………………………………………10 ThruScan sX Walk Through Metal Detector..........11 ThruScan sX-i Walk Through Metal Detector........12 ThruScan sX-WP Walk Through Metal Detector........13...
  • Page 3 Contents Page 4.1.4 Alarm & Tone Volume Adjustment.............25 4.1.5 Alarm Counter..................25 4.1.6 In-Coming / Out-Going Counter (Traffic Counts).......25 4.1.6.1 For ThruScan s3 .................25 4.1.6.2 For ThruScan s9/sX/sX-i/sX-WP .............26 4.1.7 Factory Settings..................26 4.1.8 Language Selection ................27 4.1.9 Counter Visibility..................27 4.1.10 New Password ..................27 4.1.11 Environment Noise Level ..............28...
  • Page 4 ThruScan All rights reserved. Protected by Law Number 4110 and Ideas and Works of Art Law 5846, unless a written consent by its copyright owner, Elektral A.Ş. according to the 52. Article is provided, this manual, under no circumstances may be processed, copied, its duplicated copies published, represented, presented, in any form or by any means by mechanical and/or electronic ways be transmitted or used.
  • Page 5: Praface

    Thank you for selecting a product manufactured by Elektral A.S. at an international alliance. We hope to meet at many professional Elektral products. Please make sure to read this manual carefully before start up this versatile electronic equipment.
  • Page 6: Contents

    ThruScan Technical specifications of Preparations Mounting ThruScan Programming and further procedures DO NOT OPEN ThruScan ELECTRONIC CASE RISK OF ELECTRIC SHOCK The arrow-end lightning symbol inside The exclamation mark inside the eqilateral triangle informs the equilateral triangle informs the user...
  • Page 7: Before Use

    Necessary Procedures and Safety Warnings ThruScan Prior to Using Avoid direct light from entering to the infrared sensors apertures ThruScan (see Sec. 6.10) of your ThruScan Leave minimum 1m between your and any objects such as metal doors, X-Rays, turnstiles, as such.
  • Page 8 Standards: The units conform to NILECJ L/1-3 standards ThruScan is within the magnetic emission limits approved by FDA (American Food & Drug Administration). It has been certified by experts that has no effects on the peacemakers, the pregnant women and as well at magnetic media. A “report of expertise” on this issue is presented in Attachment-1.
  • Page 9: General Description

    GENERAL DESCRIPTION ThruScan s3/s9/sX/sX-i/sX-WP WTMD’s all are simple to operate and with advanced microprocessor controlled, digital pulse induction utilizing VLF Technology that provide superior metal discrimination and detection. It is a versatile and easily portable walk-through metal detection unit providing a high level of detection with a walk-thru rate of up to 60 persons per...
  • Page 10: Thruscan

    ThruScan • International Norms (NILECJ-0601 L1-3 / IP53/ IEC 348 Class1, in accordance with CE, Manufactured in a ISO 9001-2000 certified ), • MULTIZONE, 3 “Real Detection Zone” (Left, Middle, Right), • Auto Calibration, • Compact Design, • VLF Technology- human friendly certification, •...
  • Page 11: Thruscan S9 Walk Thru Metal Detector

    Unique Designs & in variety of colours, • Easy mounting/dismounting in aprx.15 minutes, • With the Outdoor Package can be used at outside (*option), • Exported to 4 continents. NOTE: You may reach ThruScan s9 Photo Gallery through www.elektral.com.tr website.
  • Page 12: Thruscan Sx Walk Through Metal Detector

    ThruScan ThruScan sX was introduced as “The Breaking News” at Abu Dhabi –Middle East Security & Safety Exhibition-2003 with its innovative superior spec, compliance to norms, contemporary design, performance and economic advantage, in comparison to its counterparts. It’s widely used and preferred all around the world, protecting millions of people against terror •...
  • Page 13: Thruscan Sx-I Walk Through Metal Detector

    ThruScan sX–i • International Norms (NILECJ-0601 L1-3 / IP54/ IEC 348 Class1, in accordance with CE, Manufactured in a ISO 9001-2000 certified ), • MULTIZONE, 9 Real Detection Zone, • Auto Calibration, • VLF Technology- human friendly certified • Green/Red Bicolour Traffic Through LEDs, •...
  • Page 14: Thruscan Sx-Wp Walk Through Metal Detector

    ThruScan sX-WP ( Weatherproof Version) ThruScan sX-WP has the same superior features as sX even improved in weatherproofing & some other electronic features. • International Norms (NILECJ-0601 L1-3 / IP55/ IEC 348 Class1, in accordance with CE, Manufactured in a ISO 9001-2000 certified ), •...
  • Page 15: Installation Instructions

    If WTMD will be used for a short time in outdoor then use “Rain Protect Shelter (Hat)” as well as outdoor package. (See Section 7.2). ThruScan sX-WP is produced for outdoor fulfilling IP55 standards.
  • Page 16 (see 2.2.9 above). pedestrian traffic. Place the side panels to the base fixing plates, using Allen key Tighten only to prevent moving; DO NOT over tighten. ThruScan 2.2.12 Ensure that is physically stable. 2.2.13 Fully tighten all bolts with the installation spanner.
  • Page 17: Control Display Panel & Indication Information

    Control Unit. Operators should not normally need to adjust these controls, which should only be altered by a supervisor or manager in ThruScan order to change the sensitivity settings of , reset counters, perform installation adjustments and to switch the unit on /off etc.
  • Page 18: Battery Indicator

    – if the power is not restored the WTMD will then automatically shuts itself. 3.1.5 IRDA REMOTE CONTROL RECEIVER (*only for ThruScan sX/sX-i) It is the receiving LED of the pilot Remote Control Unit. 3.1.6 TRAFFIC LIGHTS The traffic lights will mimic the passage is free and possible.
  • Page 19: Traffic Lights

    • The red light indicates “Wait”. *This performance is achieved by a bi-color lamp under Control Unit at model ThruScan ZONE(INDICATOR)- LIGHTS (*) Zone (Indicator) Lights comprise by 2x6 distinct pinpoint light- arrays and are located on the side panels of the exit side of the WTMD.
  • Page 20: Relay-Contact Outputs

    RELAY CONTACT OUTPUTS (RJ11/12) ThruScan Relay contacts are present on (on the side panel as a socket output) as phone connector. The outputs; normally open(NO) and normally closed(NOFF) are activated by alarms.
  • Page 21: Programming & Set Up

    NOTE: The password should only be known and entered by the authorized personal. Only one person should hold responsibility for procedures requiring the password. The operator should only be in charge of operating ThruScan and do the security control. PROGRAM MENU ENTER PASSWORD To enter the program MENU press the SEL(√) button once.
  • Page 22 245 (the lowest sensitivity). In this very distinctive feature ; The security Level is defined and assigned by the AD-Auto Designation technique and consequently the relative, pre-selected “Security Level/Channel” is set. See Section 4.1.3 for further details. ThruScan sX-i 25 security levels(channels). All channels (except prefixed NC(nilec channel)) can be aligned to different sensitivity levels.
  • Page 23 ThruScan sX/sX-i/sX-WP: SECURITY LEVEL SENSITIVITY ADJUSTMENT NILECJ – Level 2 (factory Security Level (NC) fixed) Security Level 1 Security Level 2 Security Level 3 Security Level 4 Security Level 5 Security Level 6 Security Level 7 Security Level 8 Security Level 9...
  • Page 24: Zone Security Level & Sensitivity Level Adjustment (Sx)

    UP&DOWN buttons to select the required sub-MENU or press RUN(X) to return to the normal operating mode. 4.1.2 SECURITY LEVEL AND SENSITIVITY LEVEL, ZONE ADJUSTMENTS *for ThruScan sX/sX-i/sX-WP) ThruScan The detection areas for are divided into 3 sections; such as bottom zone(ZONE 1), ThruScan middle zone (ZONE 2) and top zone (ZONE 3).
  • Page 25: Auto Detection & Auto Sensitivity Assign (Sx)

    4.1.3 AUTO DESIGNATION AND AUTOMATIC SENSITIVITY ASSIGN * only for ThruScan sX/sX-i/sX –WP) This feature is very rare worldwide and its MENU helps the user to decide and to assign the required sensitivity level very rapidly.
  • Page 26: Alarm & Tone Volume Adjustment

    4.1.4 ALARM VOLUME & TONE ADJUSTMENT ThruScan has 10 separate alarm volume levels, in 10 different tones from 1(quietest) to 10(loudest) as well as 00, which disables the audible alarm tone (but not the visual indication). The Factory default alarm volume setting is = 05...
  • Page 27: For Thruscan S9/Sx/Sx-I/Sx-Wp

    ThruScan 4.1.6.2 FOR; s9/sX/sX-i/sX –WP ThruScan has a traffic counter monitoring both incoming and outgoing traffic through WTMD thus indicates the number of persons passing through the unit in both directions after the last memory “reset”. The IN&OUT counter values are displayed on the LCD (screen) and one can compare the difference between the two counters to find the number of persons still in the building.
  • Page 28: Language Selection

    4.1.8 LANGUAGE SELECTION English, German, Turkish and Spanish languages (others optional) can be selected to operate ThruScan as follows: LANGUAGE 1. Press UP&DOWN buttons until the LANGUAGE sub-MENU option is displayed. 2. To change the language setting press SEL(√) button to enter the language MENU.
  • Page 29: Environment Noise Level

    A higher value than the threshold noise level should be selected for sensitivity level to avoid false alarms depending the users experience and instinct. 4.1.12 PASS SENSOR *for only ThruScan sX-i) ThruScan operate to detect only the passing metal metals through archway. With this extra feature it is possible to delete this function.
  • Page 30: System Operation

    SYSTEM OPERATION ThruScan is extremely easy to operate however; the unit must be used in a proper way to ensure right detection & screening. ThruScan The operator (Security Guard-the person responsible for ) must follow the supervisor’s WTMD instructions regarding the use of with necessary response to the alarms.
  • Page 31: Alarm State

    The operator should then either scan the person with a hand-held metal detector ThruScan s-dS-dV-dX), or ask the person to re-enter the WTMD. If an alarm sounds after the person re-enter the walk-through, he/she must be rescanned with a hand-held metal detector-HHMD and the cause of activation should be determined.
  • Page 32: Language

    2) WTMD, ThruScan may display a failure code(error 19) if not used or screened for a long time. In such case try and screen your WTMd with an unclean object with metal. If error message continue pls.
  • Page 33: Memory

    LCD display. This specification may be hidden when requested (See 4.1.9). (*pls. note ThruScan s3 has only one direction counting!) TAMPER PROOF The acces to control panel is double secured by a mechanical lock. And thus it protects the access to the system controls.
  • Page 34: Electromagnetic Noise & Interference Rejection

    6.11 ELECTROMAGNETIC NOISE & INTERFERENCE REJECTION/DIRECTIVES ThruScan has integrated high quality/high-tech filter circuitry, which substantially eliminates and rejects spurious magnetic and electrical interference under norms (89/336/EEC) for itself and mains. As a result of the tests carried Conformity to CE directives, EU European Union Directives for Safety;...
  • Page 35: Operating Temperatures

    60~65 persons per minute (may vary with the metal magnitude). (* for s3 30~40 persons/min) 6.18 WEIGHT (~ kgs.) ThruScan ThruScan s3/s9 sX/sX-i Main control & display unit : 7.9 Main control & display unit : 7.9...
  • Page 36: Options

    Windows Operating System(*). (*) with the courtesy of Messrs., Microsoft Inc. The program can be installed from the factory’s web site (www.elektral.com.tr) or the floppy disk or CD given with the WTMD as an option. User’s password is required for the activation...
  • Page 37: Specific Modem For Remote Control Program

    See Section 10.2 for the Manual for this Software. ThruScan s3/s9 SR C-SCADA Software ThruScan Software sX/sX-i/sX-WP SRC-SCADA Software 7.1.2 REMOTE CONTROL (by MODEM) The second accessory of the Remote Control Package is a specially modified modem. This modem is not a standard modem. It decodes the data...
  • Page 38: Side Panel Protection

    The “protection cover” is designed to protect the side panels from drizzled rain. It is made of plastic material. BATTERY GROUP ThruScan operates for approximately 4 hours with its standard inbuilt uninterrupted power supply/UPS with batteries. It is possible to increase this duration upon demand optionally.
  • Page 39: Repair

    All parties agree that the final place of overhaul is the official premises of Elektral in Izmir-Turkey-Ataturk Industrial Zone and the transport costs or the travel costs of technicians are not beard by Elektral himself.
  • Page 40: Trouble Shooting

    This warranty is expressly in lieu of all other warranties, expressed or implied, including the warranty of merchantability or fitness for a particular purpose. The Buyer acknowledges that any oral statements about the merchandise described in this contract made by Seller’s representatives, if any such statements were made, do not constitute warranties, shall not be relied upon by the Buyer and are not a part of this contract for sale or delivery.
  • Page 41: Mounting Questions

    Also the environmental conditions should match with the security class of your WTMD. See section *Is it possible to have the mains input from Top to Bottom or Bottom to Top ThruScan ThruScan In general the standard mains input for s3/sX/sX-i/sX-WP’s is from top, for...
  • Page 42 (S3/s9; 16 pcs–sX; 99 pcs) STAR NETWORK (S3/s9; 16 pcs–sX; 99 pcs) ThruScan It is also possible to utilize separate cables for each * I want to operate my WTMD through a standard telephone line using the Remote Control SRC-SCADASoftware. How should I make the connection? You may operate and/or make the adjustments of your WTMD from anywhere around the world using a standard telephone line as cable or satellite connection (GSM or THURAYA).
  • Page 43: Operational Questions

    This cable is provided as an accessory. * What is the maximum distance could be between my computer and ThruScan It depends on the Cu-quality/Thinnet of the cable. With the cable supplied by the factory, you may have a data communication up to 100 meters.
  • Page 44 See 4.1.1 and 4.1.2 *How should I use the AD-Auto-Detection, sensitivity assignment MENU ? (*for ThruScan sX series only) Please refer to user’s manual. This MENU is designed in assigning a sensitivity level and states an approximate value. It is recommended that the Sensitivity should be further adjusted by the user, depending on experience, in cases of critical security.
  • Page 45: Appendix

    CERTIFICATE OF EXPERTISE ThruScan Certificate of Expertise, certifies that the taken, in random from the production line of Elektral A.S, conforms to the general test criteria and matches the standards envisioned throughout the world. ThruScan The Magnetic Field Strength of , appears much lower than have been stated by FDA.
  • Page 46 ThruScan (Note: During organising the network; When you communicate with selected s3/s9, you should disconnect the other Magnetic Walk-Thru Metal Detectors from your network ! ) ThruScan s3/ ThruScan To change the s9’s index number: (Only one s3/s9 has to be connected to the network) a) Arrange the communic ation.
  • Page 47: Thruscan

    ThruScan 10.2.2 sX/sX-i/sX-WP SRC-SCADA Remote Control P r o g r a m U s e r M a n u a l Please enter your Registration Code for the activation of your SRC-SCADA Remote C ontrol Programmer. You can have your Registration Code from your dealer by e-mail or telep hone.
  • Page 48: Irda Remote Control Unit Manuel

    10.3 IRDA REMOTE CONTROL UNIT MANUEL Pin Code Insertion: It is necessary to insert 4 digit pin-code (** **) to start procedures. Thus first 4 digit pin-code umbers should be entered from remote. (RUN(X)) button returns the WTMD to its operational model and exits from IRDA programming ode.
  • Page 49: Users Manuel For Wheeled Transportation

    Users manual for Wheeled Transportation Accessory /WTMD Wheeler peration: This device is designed as an accessory for the WTMD Models(all) ThruScan s3/s9/sX/sX-i/sX- WP and for transportation purposes only. To use this accessory correctly, make sure that you hav assembled the apparatus properly. The assembled WTMD should be carefully placed into the transportation accessory and then the item number (h) should be used to fix the accessory by screwing to the bottom part of the side panels.(Make sure that you are not screwing extremely...
  • Page 50: Certificate Of Warranty

    ___ YEARS Within the Warranty period, ELEKTRAL will repair or replace, without charge, any part or parts that prove to be defective. The defective instruments should be returned, accompanied by the attached SERVICE OR REPAIR CARD to ELEKTRAL Izmir Ataturk Indu strial Zone M.K.

Table of Contents