  • Page 2 GENERAL PRECAUTION Please read this manual carefully before beginning the installation of your Koolance system. This manual assumes the user has basic experience in building and configuring computer systems. Information referring to traditional hardware assembly is intentionally brief.
  • Page 3: Table Of Contents

    Alarm Set ...................... 10 Relay Set ...................... 10 CAUTION: The EXC-800 chiller is specific to one input voltage (either Pump Set ...................... 11 110VAC or 220VAC) and will not auto-switch between these voltages.
  • Page 4: System Diagram

    System Diagram Positioning the System Fill Port CAUTION: Always keep the EXC-800 chiller upright during operation. Carrying Handles Additionally, THE UNIT MUST BE KEPT UPRIGHT FOR AT LEAST 24 HOURS BEFORE POWERING ON. This is to allow enough oil to reach the compressor.
  • Page 5: Coolant Filling And Powering-On

    CAUTION: The EXC-800 chiller is specific to one input voltage (either Coolant Filling and Powering-On 110VAC or 220VAC) and will not auto-switch between these voltages.
  • Page 6: Display Panel

    TEMP SET CAUTION: This cooling system can chill liquid below the ambient air The Koolance display panel allows control and monitoring of various aspects of temperature, which may cause condensation to form on tubing and the cooling unit. 4 buttons are used, with directional arrows to navigate or change cold plates.
  • Page 7: Alarm Set

    Press to accept and return to the previous menu. the reservoir. Dry-running (and thereby damaging the pump) is not covered under the Koolance product warranty. ALARM SET (TEMP SET) ± 5C In the above example, the alarm will sound if the temperature exceeds a 5°C The pump speed can be manually set from 1 (lowest) to 10 (highest): difference (+ or -) from the chiller’s currently active temperature sensor (see “TEMP...
  • Page 8: Troubleshooting

    Troubleshooting If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values can be rotated through the front display. We hope your Koolance system will provide you with years of reliable cooling ◙ The first line will flash. Use ▼ and ▲...
  • Page 9: Limited Warranty

    No responsibility is assumed for any special incidental or consequential damages due to a defective Koolance product. In order to obtain warranty service, contact our RMA department for information. The product must be shipped postage prepaid to an authorized Koolance service location.