Hide thumbs Also See for ALX Series:

Advertisement

Quick Links

®
Superior Liquid Cooling Systems
ALX Series Products
ALX Series Products
User's Manual
User's Manual
English v1.0

Advertisement

Table of Contents
loading

Summary of Contents for Koolance ALX Series

  • Page 1 ® Superior Liquid Cooling Systems ALX Series Products ALX Series Products User’s Manual User’s Manual English v1.0...
  • Page 2 Koolance Incorporated does not warrant them. TRADEMARKS The Koolance name and logo are trademarks or registered trademarks of Koolance, Inc. Other company and product names used in this publication are for identification purposes only and may be trademarks or registered trademarks of their respective companies.
  • Page 3: Table Of Contents

    WARNING: The Koolance liquid coolant contains chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICALS OUT OF THE REACH OF CHILDREN. Please refer to the coolant MSDS available on our website: www.koolance.com CAUTION: Supply only the proper input voltage and polarity to the cooling system, as labeled below the terminals on the unit.
  • Page 4: Product Diagram

    Product Diagram ALX systems are composed of two modules physically connected together: the front “RPM” and rear “HXM”. Diagrams below are general representations, as individual module specifications and sizes can vary. RPM Reservoir and Pump Module Coolant Reservoir Reservoir Fill Port Display Panel Main Power...
  • Page 5: Positioning The System

    Positioning the System This product must be operated in an upright orientation (shown below). Alternative orientations can prevent the coolant pump from operating properly. Combining Modules If you have purchased both RPM and HXM modules, they are combined together using hardware included with those products. Install the shorter fittings included with the RPM module onto its rear inlet and outlet.
  • Page 6 Fasten the included mounting bracket to the rear of the RPM module using four bracket screws. The bracket must match the orientation shown to the right. Push the RPM and HXM modules together. Their fittings will mate and seal. Finish combining modules by securing the bracket with its remaining four screws.
  • Page 7: Wiring

    Wiring The ALX cooling system requires a 12VDC power supply (not included). Amperage for RPM and HXM modules are printed separately on their labels. These can be added together for the total power requirement and range between 2-8A. CAUTION: Supply only the proper input voltage and polarity to the cooling system, as labeled below the terminals on the unit.
  • Page 8: Tube Fittings

    Tube Fittings Tube fittings are purchased separately. Unlike the fittings used to combine RPM and HXM modules, threading for the tube fittings is tapered 1/4-inch NPT. Plumber’s tape (PTFE) is required to seal them properly. After wrapping with tape, the inlet and outlet fittings should be inserted by hand, then finished with a wrench for the last 1-2 rotations.
  • Page 9: Coolant Filling And Powering-On

    “top-off” the reservoir. An air gap must always remain to ac- commodate thermal expansion of the liquid. Slowly fill the system with coolant. To maintain the product warranty, use only Koolance approved coolant. Many alternative liquids and additives can cause permanent damage to the cooling unit (through chemical reaction, corrosion, biological growth, high thermal expansion, viscosity, etc.).
  • Page 10: Display Panel

    Display Panel The Koolance display panel allows control and monitoring of various aspects of the cooling unit. 5 buttons are used, with directional arrows to navigate or change settings, and a center button to select/exit. Navigate Up, Increase Setting ◙...
  • Page 11: Temp Set

    TEMP/FAN SET Under “TEMP/FAN SET”, you can select the active set-point temperature the system will attempt to follow, or else operate the fans at a fixed power level. There are four options to select from. Press ▼ and ▲ to scroll among them: ▲...
  • Page 12: Relay Set

    RELAY SET Terminals are provided for a configurable relay. Wires can be connected as normally-open (NO), or normally- closed (NC), labeled near the terminals. There are five options which are simultaneously active. Upon entering the relay menu, the last edited value will flash. Press ▼...
  • Page 13: Software Feature

    DISPLAY SET. Software Feature This unit supports Koolance’s “System Monitor” application for viewing cooling values and logging data to a computer file. Visit www.koolance.com/software to download the latest version of the program. Consult the application’s readme.txt for further details.
  • Page 14: Troubleshooting

    Troubleshooting We hope your Koolance system will provide you with years of reliable cooling performance. To help avoid unnecessary RMA issues, we have prepared this list of possible operational problems, and their most common solutions. 1. After filling the reservoir with coolant and turning on the system, there are no visible signs of liquid movement...
  • Page 15 No responsibility is assumed for any special incidental or consequential damages due to a defective Koolance product. In order to obtain warranty service, contact our RMA department for information. The product must be shipped postage prepaid to an authorized Koolance service location.
  • Page 16 9001 Printed in Korea...

Table of Contents