Model(s):
NBV3630I, NBV3933I,
NBV4236I, NBV4842I
B-Vent Gas Appliance
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fireplace.
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
A CO detector shall be installed in the room where the appliance
in installed.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory trained
professionals, or technicians supervised by an NFI
certified professional.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NBV3630I and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heatilator NBV3630I

  • Page 1 Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 2: Congratulations

    VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL. FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE.  = Contains updated information. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 3: Table Of Contents

    A. Appliance Dimension Diagram B. Vent System Configuration B. Service Parts List 8 Vent Clearances and Framing C. Optional Components  A. Pipe Clearances to Combustibles D. Contact Information Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 4: Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645B 04-02-09 Page 1 of 2 Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645B 04-02-09 Page 2 of 2 Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 6: Listing And Code Approvals

    Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 7: Btu Specifications

    000 feet and 4500 feet. Above 4500 feet, it is installed in locations such as in bathrooms or near consult local gas utility. sinks. Check with your local gas utility to determine proper orifice size. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 8: User Guide

    Mesh Door Outside Air Kit Section 2.E. Section 2.H. (must open mesh door to access handle) Clear Space Section 2.D. Hearth (not required) Figure 2.1 General Operating Parts Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 9: Fan Kit (Optional)

    F. Fixed Glass Assembly See Section 14.J. G. Remote Controls, Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fireplace: Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 10: Lighting Instructions (Ipi)

    NATURAL GAS Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance. 33631D Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 11: After Fireplace Is Lit

    Some optional control systems available with IPI models may allow pilot flame to remain lit. In a standing pilot system the pilot will always stay on. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 12: Maintenance And Service

    Carefully set fixed glass assembly in place on fireplace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 13: Maintenance Tasks-Qualified Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. • Replace fireplace if firebox has been perforated. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 14 Figure 3.1 IPI Pilot Flame Patterns Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 15: Installer Guide

    Ceiling Joists (SECTION 5) (SECTION 8) Optional Wall Switch Mantel & Mantel Leg (SECTION 13) Surround Hearth Extension (not required) Gas Line (SECTION 11) Figure 4.1 Typical System Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 16: Design And Installation Considerations

    Call a qualified service technician to inspect the appli- ance and to replace any part of the control system and/or gas control which has been under water. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 17: Negative Pressure

    Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment. Recommended Recommended Location Location Marginal Location Location Recommended Location Recommended Windward Leeward Multi-level Roofs Figure 4.2 Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 18: Framing And Clearances

    • Vent Clearances and Framing (Section 6) Model inches 33-1/2 19-5/8 NBV3630I inches 35-1/2 19-5/8 NBV3933I 1016 inches 37-5/8 19-5/8 NBV4236I 1067 1092 inches 41-7/8 19-5/8 NBV4842I 1219 1064 1245 Figure 5.1 Appliance Locations Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 19: Constructing The Appliance Chase

    (Height) (Depth) Model 34-7/8 19-5/8 NBV3630I 34-7/8 19-5/8 NBV3933I 36 in. (914 mm) 34-7/8 19-5/8 0 in. NBV4236I 1067 34-7/8 19-5/8 NBV4842I 1219 Figure 5.2 Clearances to Combustibles Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 20: Mantel And Wall Projections 0

    3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 5.4 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 21: Termination Locations

    Over 18/12 to 20/12 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 * 3 ft. minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 22: Vent Information And Diagrams

    Failure to keep insulation or other material away from vent Elbow pipe may cause fire. Note: Maximum horizontal distance is 50% of vertical vent height. Figure 7.3 Maximum Horizontal Run Using 45° Elbows Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 23: Vent Clearances And Framing

     in. (51 mm) above insulation. Attic shields must meet specified clearance and be se- cured in place. Use B-vent manufacturer’s firestops to provide adequate clearances. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 24: Appliance Preparation

    Secure the appliance to the floor by inserting two screws through the bottom front of the appliance. Figure 9.1 Outside Air Kit Installation Nailing Flanges (both sides) Figure 9.2 Proper Positioning ad Securing of Appliance Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 25: Installing Vent Pipe

     in. (51 mm) above insulation. Attic shields must meet vent manufacturer’s specified clearance and be secured in place per vent manufactur- er’s instructions. Figure 10.1 Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 26: Gas Information

    1/ in. (1 mm) control consult local gas utility. valve inlet. • If substituting for these components, please consult local codes for compliance. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 27: Electrical Information

    • Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 28: Electrical Service And Repair 8

    Pilot Assembly Optional Remote Junction Limit Switch Adaptor GRN* * GRN wire only used with optional wall switch WSK-MLT-HTL Valve Figure 12.2 Intellifire Pilot Ignition (IPI) Wiring Diagram Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 29: Junction Box Installation 9

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 30: Finishing

    3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 13.2 Combustible Mantel Leg or Wall Projections (Accept- able on both sides of opening) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 31: Facing Material 1

    Overlapping materials could ignite and will inter- fere with proper operation of doors and louvers. These surfaces may be covered with non-combustible Non-combustible material. sealant. Figure 13.3 Noncombustible Facing Diagram Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 32: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazad and will void the warranty. Figure 14.3 Remove Screen Package Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 33: Place The Rockwool

    Set the glass panel on the lower two or four glass assembly latches, ensuring the glass panel is centered in the opening. • Replace glass latches. See Figure 14.4. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 34: Remove Screen Protector 4

    Note: The floor cover in the bottom front of the fireplace may It is loose and can be removed/ be covering the UL labels. replaced. Figure 14.9 Removing Parts Package Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 35: Close The Screen Assembly 5

    Figure 14.14 Rotate the Screen Down Figure 14.12 Magnetic Touch Latch Open Hang Screen on Shoulder Screws Figure 14.15 Press on Bottom of Screen Figure 14.13 Hang Screen Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 36: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least .7 volts. Replace batteries if volt- solenoid ohms readings. age is below .7. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 37 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 38: Reference Materials

    Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 39: Service Parts List 9

    B. Service Parts List Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 40 B. Service Parts List (continued) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 41 B. Service Parts List (continued) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 42 B. Service Parts List (continued) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 43 B. Service Parts List (continued) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 44 B. Service Parts List (continued) Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 45: Optional Components

    FFDEMI0 Non-operable Decorative Front FFDEMI Non-operable Decorative Front DFNMESH0 Mesh Front DFNMESH Mesh Front DFNMESH0M Multi Pack of 4 Mesh Fronts DFNMESHM Multi Pack of 4 Mesh Fronts Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 46 FFDEMI6 Non-operable Decorative Front FFDEMI4 Non-operable Decorative Front DFNMESH6 Mesh Front DFNMESH4 Mesh Front DFNMESH6M Multi Pack of 4 Mesh Fronts DFNMESH4M Multi Pack of 4 Mesh Fronts Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 47 [432 mm] 9-3/8 in. [238 mm] LDS-BV Decorative Shroud TCG375 Terra Cotta Cap Catalog # 1.5 15.5 LDS-BV See your Heatilator dealer for a complete listing of optional components. Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...
  • Page 48: Contact Information

    674894, 676946, 677480, 67960, 684061, 6848441, 686064, 686605, 686978, 687501, 688075, 690809, 6919884, D065, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2008 Heatilator • Novus B-Vent Series • 4055-188 • Rev I • 08/09...

This manual is also suitable for:

Nbv4236iNbv4842iNbv3933i