Table of Contents Purpose of the System ............3 Setup Instructions ..............4 Armband Operating Instructions.......... 4 Proper Wear and Cleaning..........4 Removing the Armband strap from the Armband ..6 Armband Status Indicators ..........6 Display (optional accessory) Operating Instructions ..8 Using the Display ............
Table of Contents Purpose of the System User Environment ..............24 Intended Use The system records and analyzes physiological parameters, and uses algorithms Regulatory Statement ............28 to report daily movement, calories burned, degree of physical activity, and steps Copyright, Patent, and Trademark Notice ......30 taken.
Setup Instructions Please refer to the Quick Start included in the package for instructions on how 4. Wear the Armband no more than 23 hours a day. to begin using the system. It only takes a few minutes to get set up and moving Be sure to leave it off 1 hour per day.
Removing the Armband strap from the Armband • Green (solid) = More than 24 hours of battery life remain. You will need to remove the Armband from its strap to upload data or to clean the • Amber (flashing) = Less than 24 hours of battery life remain. Armband.
Display (optional accessory) Operating Instructions The Display is an optional accessory intended for use with the Armband. It allows 3. The Display will read PRESS ARMBAND BUTTON TO SYNC. The Display you to easily view your up-to-the-minute information including calories burned, must be within 3 feet of the Armband.
Display Overview View Functions The View button allows you to toggle between data collected TODAY or YESTER- The Display has an LCD and four buttons: DAY, or to view your TARGET or TRIP information. • MODE • TODAY View: The TODAY view shows current values for the current •...
Display Battery more. The Display will turn on and the back-light will flash. Follow the instructions for “Using the Display” on page 8 to synchronize again with the Armband. If the digits on the Display are faded, and you can not establish a connection to the Armband, then the battery may require replacing.
Symbol Definitions use solvents, cleaners or other chemicals to clean the Armband or Display and do Follow operating instructions not sterilize either part. Avoid the use of lotions or other chemicals on the skin. CAUTION Cleaning To clean the Armband and Display: Non-Ionized radiation 1.
Cautions CAUTION: Always consult a physician before starting any new diet or exercise CAUTION: The equipment is not suitable for use in the presence of a program. This system is not to be used for diagnostic purposes and is not FLAMMABLE ANESTHETIC MIXTURE WITH AIR OR WITH OXYGEN OR intended to be a substitute for the medical advice or supervision of your NITROUS OXIDE.
Safe Disposal CAUTION: Check the equipment for sharp edges or damage before each use. If you want to dispose of the Armband or Display, please do not use the ordinary trash. These products must not be disposed of with your other household waste. CAUTION: If the Display is dropped, ensure that it is working properly and Dispose of the Armband or Display equipment by taking them to a designated col- not physically damaged before relying on its readings.
Troubleshooting For troubleshooting information and additional resources, please refer to the Help Display section on www.bodymedia.com. • User-replaceable coin cell battery (CR-2032) • RF Frequency: 2.4 GHz wireless communication interface • Transmitter output power: <1mW • Size: 40 mm diameter, height: 19 mm with clip •...
Skin Temperature This Limited Warranty is subject to compliance with the applicable user guides for the BodyMedia Hardware and does not apply to normal wear and tear or damage caused by improper or incor- Calibrated Range is 20.0ºC to 40.0ºC rectly performed maintenance, negligence, accident, misuse or unreasonable use, modification, A minimum resolution of 0.05ºC tampering, or any other causes not related to design, materials or workmanship.
User Environment Guidance and Manufacturer’s Declaration - Immunity The Armband and Display are intended for use in the electromagnetic environment 2.5m specified below. The customer or user of the Armband and Display should ensure 1.5m that it is used in such an environment. 1.5m 1.5m IEC 60601...
Page 15
Guidance and Manufacturer’s Declaration - Emissions Recommended Separation Distances for the Product The Armband and Display are intended for use in the electromagnetic environment The Armband and Display are intended for use in the electromagnetic environment specified below. The customer or user of the Armband and Display should ensure specified below.
FCC 47CFR Part 15 Subpart C Intentional Radiator Tests (Model DD100) comply with part 15 of the FCC rules. Operation is subject to the following ETSI EN 301 489-1 with ETSI EN 301 489-17 (Article 3.1(b) of R&TTE Directive) 2.4GHz.
Page 17
Copyright, Patent and Trademark Notice The products and services which include the software, firmware, algorithms, processes, and methods of BodyMedia FIT™, SenseWear® applications as well, all devices and components used therewith including the Armband, Display, and Wireless Communicator, are covered by one or more of the following patents: United States Patent Nos.: D439,981, 6,527,711, 6,595,929, 6,605,038, 7,020,508, 7,153,262, 7,261,690, 7,285,090 and 7,502,643;...
Need help?
Do you have a question about the DD100 and is the answer not in the manual?
Questions and answers