Electrical Output
Electrical Output
Electrical Output
Electrical Output
Electrical Input
Electrical Input
Electrical Input
Electrical Input
Battery
Battery
Battery
Battery
Extended Runtime Module Supports up to two ERMs (PN 217800-B21)
Extended Runtime Module
Extended Runtime Module
Extended Runtime Module
Communications
Communications
Communications
Communications
Environmental and Safety Operating Temperature
Environmental and Safety
Environmental and Safety
Environmental and Safety
Online Regulation
Online Regulation
Online Regulation
Online Regulation
On battery Regulation
On battery Regulation
On battery Regulation
On battery Regulation
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Output Connections
Output Connections
Output Connections
Output Connections
Output Protection
Output Protection
Output Protection
Output Protection
(Circuit breakers)
(Circuit breakers)
(Circuit breakers)
(Circuit breakers)
Voltage Range
Voltage Range
Voltage Range
Voltage Range
Frequency
Frequency
Frequency
Frequency
Input connection
Input connection
Input connection
Input connection
Online Efficiency
Online Efficiency
Online Efficiency
Online Efficiency
Surge Suppression
Surge Suppression
Surge Suppression
Surge Suppression
Input Current
Input Current
Input Current
Input Current
Inrush Current
Inrush Current
Inrush Current
Inrush Current
Type
Type
Type
Type
Backup Time
Backup Time
Backup Time
Backup Time
Typical Recharge Time
Typical Recharge Time
Typical Recharge Time
Typical Recharge Time
Type
Type
Type
Type
Backup Time
Backup Time
Backup Time
Backup Time
Recharge Time
Recharge Time
Recharge Time
Recharge Time
Serial Ports
Serial Ports
Serial Ports
Serial Ports
Management Software
Management Software
Management Software
Management Software
Included
Included
Included
Included
Control Panel
Control Panel
Control Panel
Control Panel
Front Panel Button
Front Panel Button
Front Panel Button
Front Panel Button
Controls
Controls
Controls
Controls
LED Indicators
LED Indicators
LED Indicators
LED Indicators
Audible Alarms
Audible Alarms
Audible Alarms
Audible Alarms
Operating Temperature
Operating Temperature
Operating Temperature
Transit Temperature
Transit Temperature
Transit Temperature
Transit Temperature
Storage Temperature
Storage Temperature
Storage Temperature
Storage Temperature
Operating Humidity
Operating Humidity
Operating Humidity
Operating Humidity
Storage Humidity
Storage Humidity
Storage Humidity
Storage Humidity
Operating Altitude
Operating Altitude
Operating Altitude
Operating Altitude
Transit Altitude
Transit Altitude
Transit Altitude
Transit Altitude
Storage Altitude
Storage Altitude
Storage Altitude
Storage Altitude
DA - 11395
North America — Version 10 — September 9, 2005
± 3% of nominal
± 3% of nominal
Sine wave
Hardwired (x1 40A PDU shipped with the UPS, p/n: 252663-B21; (32)
IEC320-C13 & (4) IEC320-C19 outlets; 0U/1U).
The UPS does not have any output circuit breakers (on the input-end, the
UPS will need a 100A circuit with over current protection). When a HP PDU
is hardwired to the UPS, the output circuit breaker protection is provided by
the PDU circuit breakers.
200-240 VAC
50/60 Hz ± 5Hz (auto sensing)
Hardwired, single phase
>83%
High energy 6500A peak;
88A maximum
(100A circuit breaker is recommended upstream from UPS)
100A peak maximum
Each module contains maintenance-free, sealed valve regulated lead-acid
(VRLA) batteries with an 8-year min. float service. Each Battery Module
consists of four 12v Lead Acid batteries.
See Backup Times Chart
< 3 hours to 80% usable capacity; < 48 hours for complete recharge
Two battery modules in a 4U chassis; (4) 12V 42AH batteries; (2) batteries
on (2) trays.
Extends runtime 15 min. at 80% load
80% in 8 hrs
Two; DB9 RS232 connectors
Yes
LCD Front Panel display to configure and monitor UPS
2 line x 16 character LCD display; 7 languages (English, French, Spanish,
German, Japanese, Italian, Dutch, Danish)
Six-button control
Five modes of operation; standby, operate, bypass, battery, and redundant.
Yes
50° to 104° F (10° to 40° C)
-13° to 131° F (-25° to 55° C)
32° to 77° F (0° to 25° C)
5% to 95%; non-condensing
5% to 95%
Up to 10,000 ft (3048m) (0 to 4000 ft de-rated linearly to 80% at 10000 ft)
49,212 ft (15,000 m) above sea level
0 to 30,000 ft (9,144 m) above sea level
UPS R12000 XR, N+X
UPS R12000 XR, N+X
UPS R12000 XR, N+X
UPS R12000 XR, N+X