We recommend the elimination of the water savers on the back of the shower
heads if a repeat interruption of the hot water occurs.
Any problem of the installation and maintenances can be asked at:
Other factors to be taken in consideration
OME 514-PV Outlet Temperature Chart
Flow Rate
45 F
GPM
Inlet Temp.
2.75
130*
3.00
124
3.25
116
3.50
109
3.75
104
4.00
101
4.25
95
4.50
92
4.75
89
5.00
86
5.25
84
* The result for Output temperature was reduced to 130 Degrees, by the temperature safety devices (anti-scalding
device) included in the design of the unit.
** The normal shower temperature
Warning
:
Exposure to water at 125*F can produce first degree burns in 15 seconds
Typical Flows and Temp for Household Fixtures
Fixture
Type
Lavatory
---->
Flow Rates
0.8 - 1.5 1.0 -1.7
Prevailing
80°
Temp.
to
Use
105°
Flow Rates in Gals/ Minute
Temperature in degrees °F
* Energy Department website defines a "Legal" shower as a shower which use no more then
1.76 gallons/minute.
** All 10 years old or newer Dishwashers have their own heater element so incoming water
temperature is somehow irrelevant.
888-866-2118
Monday to Friday 9.00 Am to 5.00 PM
50 F
Inlet Temp.
Inlet Temp.
130*
129
121
114
109
104
101
97
94
91
89
Shower
Shower
High
Low flow
flow
1.7-
3.0*
100°
to
110°
55 F
60 F
Inlet Temp.
130*
130*
130*
130*
126
130*
119
124
114
119
109
114
105
110
102
107
99
104
96
101
94
99
Kitchen
Bathtub
Sink
Jacuzzi
1.0 -1.5
2.0-4.0
105°
90°
to
to
115°
110°
8
70 F
65 F
Inlet
Inlet Temp.
Temp
130*
130*
130*
130*
130*
130*
129
130*
124
130
119
125
115
120
112
117
109
114
106
111
104
109
Dish
Washing
Washer
Machine
1.0-1.5
1.5-2.0
105°
80°
to
to
115°**
95 °

Hide quick links:

Advertisement

loading