Instantaneous water heater

Advertisement

Pressure
Temperature relief valve
NOTE:
/
is not necessary or required because the
unit has a integrated, redundant over
temperature protection system.
Gas Installation
The gas line is from the bottom of the unit:
Connect the gas unit thru hard line or a
approved flex hose not less then ½ "diameter.
You can use your old flex hose if is sufficient
long and at of list ½" diameter.
Warning:
Your line has to have a minimum
pressure of 0.33 PSI and the capacity to
move a sufficient quantity of gas to
produce 112,000 Btu.
Lengthy gas pipe with out step-downs
will not be able to supply the necessary
gas volume for the unit.
Warning:
The unit will not work if
not pluged on a electrical receptacle
with a working ground connection.
The freezing device is not adjustable, do not
turn or disassemble. Only a authorized
technician can perform maintenance on the
anti-freezing device
Maintenance
The unit is virtual maintenance free with the
exception of the de-scaling every 1 to 3 years
based of the PH of the local water supply. The
harder is the water, more often the de-scaling
has to be done. Ask a local professional for
advice in regard to the composition of the
water. Your local Water Company or your local
Gas Company can help you with the necessary
data.
De-scaling involve harsh chemicals and
specialized tools and can only be done by a
professional.
Warning!
-Do not attempt to do it yourself.
-Severe burns can occur if no
specialize equipment are used
-Improper chemicals can harm the
water heater and/or the plastic and
rubber parts rendering the warranty
void.

Operation

-Plug the electrical cord on the electrical
receptacle.
-Open the water valve
-Check for leaks
-Open the gas valve
-Check for leaks
Warning:
Do not check for gas leaks with an open
flame. Severe burns and/or fire can be
produced in case of gas leaks.
- Adjust the gas knob to maximum
-Adjust the water knob to maximum volume of
water
- Open a water faucet as close as possible to
the unit.
6